Research on Transmission Line Voltage Measurement Method of D-Dot Sensor Based on Gaussian Integral
Jingang Wang1, Yanhang Zhao2, Wenjiang Li3
1State Key Laboratory of Power Transmission Equipment & System Security and New Technology, Chongqing University, Chongqing 400044, China. jingang_023@163.com.
Abstract:
D-dot sensors meet the development trend towards the downsizing, automation and digitalization of voltage sensors and is one of research hotspots for new voltage sensors at present. The traditional voltage measurement system of D-dot sensors makes possible the reverse solving of wire potentials according to the computational principles of the electric field inverse problem by measuring electric field values beneath the transmission line. Nevertheless, as it is limited by the solving method of the electric field inverse problem, the D-dot sensor voltage measurement system is struggling with solving difficulties and poor accuracy. To solve these problems, this paper suggests introducing a Gaussian integral into the D-dot sensor voltage measurement system to accurately measure the voltage of transmission lines. Based on studies of D-dot sensors, a transmission line voltage measurement method based on Gaussian integrals is proposed and used for the simulation of the electric field of a 220 kV and a 20 kV transmission line. The feasibility of the introduction of the Gaussian integral to solve transmission line voltage was verified by the simulation results. Finally, the performance of the Gaussian integral was verified by an experiment using the transmission line voltage measurement platform. The experimental results demonstrated that the D-dot sensor measurement system based on a Gaussian integral achieves high accuracy and the relative error is lower than 0.5%.
More Related Videos
11:06A Human-machine-interface Integrating Low-cost Sensors with a Neuromuscular Electrical Stimulation System for Post-stroke Balance Rehabilitation
Published on: April 12, 2016
09:57Imaging Membrane Potential with Two Types of Genetically Encoded Fluorescent Voltage Sensors
Published on: February 4, 2016
Related Concept Videos
Gaussian Elimination: Problem Solving
Velocity and Position by Integral Method
Consider an example to calculate the velocity and position from the acceleration function. A motorboat is traveling at a constant velocity of 5.0 m/s when it starts to decelerate to arrive at the dock. Its acceleration is...
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Voltage
The Dot Product