Accuracy of predicted orthogonal projection angles for valve deployment during transcatheter aortic valve replacement
Arie Steinvil1, Gaby Weissman2, Andrew W Ertel2
1Division of Interventional Cardiology and the MedStar Cardiovascular Research Network, MedStar Washington Hospital Center, Washington, DC, 20010, USA; Sackler School of Medicine, Tel Aviv University, Tel Aviv, Israel.
Background:
Multi-detector computed tomography (MDCT) predicted orthogonal projection angles have been introduced to guide valve deployment during transcatheter aortic valve replacement (TAVR). Our aim was to investigate the accuracy of MDCT prediction methods versus actual angiographic deployment angles.
Methods:
Retrospective analysis of 2 currently used MDCT methods: manual multiplanar reformations (MR) and the semiautomatic optimal angle graph (OAG). Paired analysis was used to compare the 2-dimensional distributions and means.
Results:
We included 101 patients with a mean (±SD) age of 81 ± 9 years. The MR and OAG methods were used in 46 and 55 patients, respectively. A ≥5% change from the predicted MDCT range in left anterior oblique/right anterior oblique (LAO/RAO) and the cranial/caudal (CRA/CAU) angle occurred in 42% and 58% of patients, respectively. The mean predicted versus actual deployment angles were significantly different (CRA/CAU: -2.6 ± 11.5 vs. -7.6 ± 10.7, p < 0.001; RAO/LAO 8.1 ± 10.9 vs. 9.5 ± 10.6, p = 0.048; respectively). The MR method resulted in a more accurate CRA/CAU angle (CRA/CAU: -4.6 ± 11.1 vs. -6.5 ± 11.8, p = 0.139; RAO/LAO 7.4 ± 11.2 vs. 10.4 ± 11.2, p = 0.008; respectively), whereas the use of the OAG resulted in a more accurate RAO/LAO angle (CRA/CAU: -0.9 ± 10.8 vs. -9±11.2, p < 0.001; RAO/LAO 9.05 ± 10.6 vs. 8.5 ± 9.9, p = 0.458; respectively). For the entire cohort, the 2-dimensional distributions and means of the predicted versus the actual angles were significantly different from each other (p < 0.001). We repeated our analysis using both MDCT methods and demonstrated similar results with each method.
Conclusions:
Currently used MDCT methods for TAVR implantation angles are significantly modified before actual valve deployment. Thus, further refinement of these prediction methods is required.
More Related Videos
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Orthogonal Trajectories
Uncertainty in Measurement: Accuracy and Precision