Related Experiment Video
Updated: Feb 7, 2026

Development of a Virtual Reality Assessment of Everyday Living Skills
Published on: April 23, 2014
Use of Virtual Comparison Software for Preparation Depth Assessment in a Dental Technique Skills Course
Ramtin Sadid-Zadeh1, Upoma Guha2, Hema Arany2
1Ramtin Sadid-Zadeh, DDS, MS, is Assistant Professor, Department of Restorative Dentistry, University at Buffalo School of Dental Medicine; Upoma Guha, BDS, MS, is Clinical Assistant Professor, Department of Restorative Dentistry, University at Buffalo School of Dental Medicine; and Hema Arany, BDS, MDS, CAGS, is Clinical Instructor, Departments of Restorative Dentistry and of Pediatric and Community Dentistry, University at Buffalo School of Dental Medicine rsadidza@buffalo.edu.
Abstract:
The aims of this study were 1) to determine whether the Compare software Comparison% score provided appropriate feedback for preparation depth on a non-anatomical tooth and 2) to define an acceptable tolerance for use in calculating the Comparison% for virtual assessment of cavity depth on a non-anatomical mandibular first molar. Forty-six non-anatomical ivorine teeth with laser-marked outlines on their occlusal surfaces were used for this study. One tooth was prepared at a 1.5 mm depth, approved by participating faculty at a U.S. dental school, and served as the standard preparation. The remaining teeth were divided into three groups (n=15 per group) for cavity preparation depths of 1 mm, 1.5 mm, and 2 mm in the laser-engraved external outline. Teeth were prepared using an electric handpiece with a 330 bur and a hatchet. Virtual images of the standard and experimental tooth preparations were recorded using an intraoral scanner. Virtual comparison software was then used to superimpose a three-dimensional (3D) image of each experimental preparation on the 3D image of the standard preparation. The software calculated comparison surface percentage values (Comparison%) at a 100 and 200 micron tolerance for each specimen. Two-way mixed linear models (α=0.01) were adopted to compare outcomes for the two levels of tolerance for teeth with different depths of preparation. Using a tolerance level of 200 μm, Comparison% scores for the acceptable preparation depth of 1.5 mm were found to be significantly different (p<0.01) from those of the unacceptable 1 mm and 2 mm depth preparations. These findings suggest that virtual comparison software may be used to assess an acceptable depth for cavity preparation within a defined external outline.
Related Concept Videos
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Virtual Work
In static equilibrium, a body can experience an imaginary or virtual movement, such as displacement or rotation. The virtual work done by a force is equal to the dot product of force and virtual displacement in the direction of the force. When it comes to virtually rotating a...
Uniform Depth Channel Flow
Depth Perception and Spatial Vision
Uniform Depth Channel Flow: Problem Solving

