Size-Dependent Voltammetry at Single Silver Nanoelectrodes

Hongmei Hua1, Yong Liu1, Dongmei Wang1

  • 1Anhui Key Laboratory of Chemo/Biosensing, College of Chemistry and Materials Science , Anhui Normal University , Wuhu , Anhui 241000 , P.R. China.

Analytical Chemistry
|August 4, 2018
PubMed
Summary

Researchers studied electro-oxidation of single silver nanoelectrodes. Smaller electrodes showed faster electron transfer and favorable thermodynamics, advancing single-nanoparticle electrochemistry.

Related Concept Videos

Voltammetry: Overview01:20

Voltammetry: Overview

Voltammetry is an electroanalytical technique in which the current flowing through an electrochemical cell is measured as a function of applied potential, typically under conditions of concentration polarization. The technique provides valuable information about redox-active species, and the current response is plotted as a voltammogram.
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
2.9K
Voltammetry: Factors Affecting Measurements01:21

Voltammetry: Factors Affecting Measurements

A current produced due to the redox reactions of the analyte at the working and auxiliary electrodes is called a faradaic current. The reaction can be divided into two types. The current generated due to the reduction of the analyte is called cathodic current, and it carries a positive charge. In contrast, the current produced by analyte oxidation is known as an anodic current, and it has a negative charge. The applied potential at the working electrode determines the faradaic current flow, and...
588
Voltammetry: Stripping Methods01:13

Voltammetry: Stripping Methods

Anodic Stripping Voltammetry (ASV), Cathodic Stripping Voltammetry (CSV), and Adsorptive Stripping Voltammetry (AdSV) are electrochemical techniques used to determine trace amounts of analytes in solution. These methods involve applying a potential to an electrode and measuring the resulting current.
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
979
Voltammetric Techniques: Pulse Voltammetry01:17

Voltammetric Techniques: Pulse Voltammetry

Differential-pulse voltammetry (DPV) is a type of voltammetry that involves applying a series of voltage pulses to an electrochemical cell while measuring the resulting current. In DPV, the differential pulse or small potential pulses are superimposed on a linear potential sweep. The magnitude of these pulses is typically small, often in the millivolt range. Each voltage pulse lasts a short duration, usually in the order of a few milliseconds, and is applied at regular intervals along the...
1.6K
Cell Size01:22

Cell Size

Cell sizes vary widely among and within organisms. Bacterial cells range between 1-10 micrometers (μm)and are considerably smaller than most eukaryotic cells. The smallest bacteria are 0.1 μm in diameter—about a thousand times smaller than eukaryotic cells, which typically range from 10-100 μm.
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
128.9K
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
1.6K