Related Experiment Video
Updated: Feb 6, 2026

A Pipeline for 3D Multimodality Image Integration and Computer-assisted Planning in Epilepsy Surgery
Published on: May 20, 2016
Three-dimensional planning accuracy and follow-up protocol in orthognathic surgery: a validation study
E Shaheen1, S Shujaat1, T Saeed2
1OMFS IMPATH Research Group, Department of Imaging & Pathology, Faculty of Medicine, KU Leuven & Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium.
Abstract:
The purpose of the study was to propose and validate a three-dimensional (3D) tool for the assessment of orthognathic surgery planning accuracy and postoperative follow-up. A total of 15 patients (four male, 11 female; mean age 29.6 years) with skeletal class II and III, who underwent bimaxillary surgery were recruited for the study. All patients had preoperative computed tomography (CT), and cone-beam computerized tomography (CBCT) scans 1-6 weeks and 6 months postoperatively. The data was exported to a customized stepwise module developed in Amira software resulting in the accuracy being presented as translational and rotational differences between the planning and the actual outcome. To evaluate the reliability of the proposed method, intra-class correlation coefficient (ICC) was applied at a 95% confidence interval on the translational and rotational output of two observers. The inter- and intra-observer reliability were found to be high (ICC range: 0.94-0.98) with mean variability of less than 0.4mm and 0.7° for translational and rotational movements for both planning accuracy and follow-up protocols. The study provides a reliable, quantitative and time-efficient method for evaluating the accuracy of virtual surgical planning and postoperative follow-up.
More Related Videos
06:14In Vivo Protocol of Controlled Subconcussive Head Impacts for the Validation of Field Study Data
Published on: April 18, 2019
05:51Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Related Concept Videos
Reliability and Validity
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...