Related Experiment Video
Updated: Feb 6, 2026

Generating a Fractal Microstructure of Laminin-111 to Signal to Cells
Published on: September 28, 2020
Corrosion protection of Al(111) by 8-hydroxyquinoline: a comprehensive DFT study
Fatah Chiter1, Marie-Laure Bonnet, Corinne Lacaze-Dufaure
1CIRIMAT, Université de Toulouse, CNRS, INPT-ENSIACET 4, allée Emile Monso, BP 44362, 31030 Toulouse Cedex 4, France. corinne.dufaure@ensiacet.fr.
Abstract:
8-Hydroxyquinoline (8HQ) is a new green corrosion inhibitor. DFT-D calculations are performed to investigate the adsorption of 8HQ and derivatives on the Al(111) surface from low to high coverage. From θ = 0.20 to 0.66, the adsorption energies are -1.12, -2.41, -1.66 and -3.44 eV per molecule for 8HQ, and its tautomer, its hydrogenated and its dehydrogenated species, independently of the coverage. In contrast, the geometry of the adsorbates changes between coverage up to 0.66 and the full monolayer (θ = 1). The creation of a dipole at the molecule/metal interface reduces the work function of aluminum. To further evaluate the modification of the reactivity of the surface, adsorption of O2 on the Al(111) surface covered by the organic layer is investigated. O2 dissociation takes place for θ = 0.66. When the Al surface is fully covered (θ = 1), the reduction of O2 and the oxidation of Al atoms do not occur.
Related Concept Videos
Corrosion
Relation of DFT to z-Transform
To understand how the DFT works, it's helpful to consider the z-transform, which is a method for representing discrete sequences in the complex frequency domain. The z-transform involves summing the...
Corrosion of Reinforcement
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
Protection of Alcohols
Protection
It defines a protecting group as the masking agent to make the more reactive species inert to a given set of conditions. This concept is depicted via the illustration of liquid flow through different outlets in an assembly of pipes. The analogy helps to understand the role...
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...