NORMATIVE VALUES FOR A NEW WATER-PERFUSED HIGH RESOLUTION MANOMETRY SYSTEM
Rogério Mariotto Bitetti da Silva1, Fernando A M Herbella1, Daniel Gualberto1
1Universidade Federal de São Paulo, Escola Paulista de Medicina, Departamento de Cirurgia, São Paulo, SP, Brasil.
Background:
Esophageal manometry is the most reliable method to evaluate esophageal motility. High resolution manometry (HRM) provides topographic contour colored plots (Clouse Plots) with simultaneous analysis from the pharynx to the stomach. Both solid state and water-perfused systems are available.
Objective:
This study aims to determinate the normative data for a new water-perfused HRM.
Methods:
HRM was made in 32 healthy volunteers after 8 hours fasting. HRM system used consisted of a 24-channel water-perfused catheter (Multiplex, Alacer Biomedica, São Paulo, Brazil). The reusable catheter is made of polyvinyl chloride (PVC) with 4.7 mm of diameter. Side holes connected to pressure transducers are spaced 2 cm for the analysis from the pharynx to the lower esophageal sphincter (LES). Holes are spaced 5 mm and 120° in a spiral disposition in the LES area. The sensors encompass 34 cm in total. Upper esophageal sphincter (UES) parameters studied were basal and relaxation pressures. Esophageal body parameters were distal contractile integral (DCI), distal latency (DL) and break. LES parameters studied were basal pressure, integrated residual pressure (IRP), total and abdominal length. Variables are expressed as mean ± standard deviation, median (interquartile range) and percentiles 5-95th.
Results:
All volunteers (17 males, aged 22-62 years) completed the study and tolerated the HRM procedure well. Percentiles 5-95th range were calculated: Upper Esophageal Sphincter (UES) basal pressure 16.7-184.37 (mmHg), DL: 6.2-9.1 (s), DCI: 82.72-3836.61 (mmHg.s.cm), break: <7.19 (cm), LES basal pressure: 4.89-37.16 (mmHg), IRP: 0.55-15.45 (mmHg).
Conclusion:
The performance and normative values obtained for this low-cost water-perfused HRM seems to be adequate for clinical use.
Related Concept Videos
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values
z Scores and Unusual Values
This score indicates how far a value is from the mean in terms of standard deviation. For example, if a data value has a z score of +1, the researcher can infer that the particular data value is one standard deviation above the mean. If another data...
Absolute and Local Extreme Values
States of Water
Water freezes when the intermolecular forces are greater than the kinetic energy. Unlike most other substances, water is less dense in its solid state than in its liquid state. This is because each water molecule can form...