CMOS-compatible biosensor for L-carnitine detection
M S Andrianova1, E V Kuznetsov1, V P Grudtsov1
1Scientific-Manufacturing Complex Technological Centre, 124498, Shokina square, h. 1, bld. 7, Zelenograd, Moscow, Russia.
Abstract:
A CMOS-compatible ISFET with a Ta2O5 sensitive surface was developed. The structure was optimized for achieving high sensitivity using a subthreshold operation mode and by reducing the influence of the capacitances on the value of subthreshold swing. The developed ISFET was used as a basis for a biosensor for L-carnitine detection. To this end, carnitine acetyltransferase was immobilized on the ISFET sensitive surface. The immobilized enzyme was active (0.082 U/g model plate). The complete microsystem, consisting of a packaged chip, an immobilized enzyme and a microfluidic channel, detected L-carnitine at a range of 0.2-100 μM with a LOD of 0.2 μM. The biosensor response was linear in the range of 0.2-50 μM of L-carnitine with sensitivity 18.0 ± 1.7 mV/μM. An experiment with artificial urine containing 1.3 μM L-carnitine showed that the proposed biosensor could be used on a real sample. Therefore, a new sensor specially optimized for biosensing CMOS-compatible ISFET structures and direct determination of L-carnitine with immobilized carnitine acetyltransferase was developed.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...