Performance of the 10-2 and 24-2 Visual Field Tests for Detecting Central Visual Field Abnormalities in Glaucoma
Zhichao Wu1, Felipe A Medeiros2, Robert N Weinreb3
1Hamilton Glaucoma Center, Department of Ophthalmology, University of California, San Diego, La Jolla, California, USA; Centre for Eye Research Australia, Royal Victorian Eye and Ear Hospital, East Melbourne, Victoria, Australia; Ophthalmology, Department of Surgery, The University of Melbourne, Melbourne, Victoria, Australia.
Purpose:
To compare the performance of the pattern standard deviation (PSD) values derived from the central 12 locations of the 24-2 visual field test (C24-2) to the entire 10-2 test for detecting central visual field abnormalities in eyes with, suspected of having, or at risk of having glaucoma.
Design:
Cross-sectional case-control study.
Methods:
Eyes with, suspected of having, or at risk of having glaucoma, based on masked grading of optic disc stereophotographs and/or ocular hypertension (intraocular pressure ≥ 22 mm Hg) were included as cases (n = 523). Eyes from healthy participants were included as controls (n = 107) to allow the 2 tests to be compared at matched specificities. The sensitivity to detect cases at 95% specificity using PSD values derived from the entire 10-2 test and C24-2 were compared.
Results:
The sensitivity of the 10-2 and C24-2 PSD values was not significantly different between the 10-2 and C24-2 at matched specificities (35.9% and 35.4% respectively; P = .900). There was also a substantial agreement between the cases detected by both methods (kappa = 0.80 ± 0.04), and a very strong association between the PSD values from the 2 methods (R2 = 0.91).
Conclusions:
10-2 and 24-2 tests identified a similar number of eyes with, suspected of having, or at risk of having glaucoma as having central visual field abnormalities using PSD values. These findings do not mean that 10-2 tests are not useful, but highlight the need for further studies to determine the potential advantages of 10-2 tests through equivalent comparisons against 24-2 tests to ensure appropriate recommendations are made about its incorporation into the glaucoma standard of care.
More Related Videos
07:45Assessing Binocular Central Visual Field and Binocular Eye Movements in a Dichoptic Viewing Condition
Published on: July 21, 2020
11:12Driving Simulation in the Clinic: Testing Visual Exploratory Behavior in Daily Life Activities in Patients with Visual Field Defects
Published on: September 18, 2012
Related Concept Videos
meta-Directing Deactivators: –NO2, –CN, –CHO, –⁠CO2R, –COR, –CO2H
Crystal Field Theory - Octahedral Complexes
To explain the observed behavior of transition metal complexes (such as colors), a model involving electrostatic interactions between the electrons from the ligands and the electrons in the unhybridized d orbitals of the central metal atom has been developed. This electrostatic model is crystal field theory (CFT). It helps to understand, interpret, and predict the colors, magnetic behavior, and some structures of coordination compounds of transition metals.
CFT focuses on...
Field Effect Transistor
Electric Field
In the new picture, imagine that the first charge sets up an electric field independent of all other charges in the universe. When another charge comes in its vicinity, the second charge experiences an electric force depending on the electric field at that point. The source charge does not...
Magnetic Fields
A magnetic field is defined by the force that a charged particle experiences...
Electromagnetic Fields
However, the observation of...