Related Experiment Video
Updated: Aug 14, 2026

07:11
Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
IOP Stress Testing Identifies Glaucoma Eyes at Risk of Fast Progression Despite Controlled Office Pressure
Davina A Malek1, Felipe A Medeiros1
1Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, Miami, FL, USA.
American Journal of Ophthalmology
|August 12, 2026
Summary
Intraocular pressure (IOP) stress testing, like the water-drinking test (WDT), can identify glaucoma patients at higher risk for disease progression. This IOP stress test provides crucial information beyond standard office IOP measurements for managing glaucoma.
Area of Science:
- Ophthalmology
- Glaucoma Research
- Intraocular Pressure Management
Background:
- Glaucoma management relies on controlling intraocular pressure (IOP) to prevent functional and structural damage.
- Standard office IOP measurements may not fully capture an individual's risk for glaucoma progression.
- Identifying patients at risk despite seemingly controlled IOP is crucial for timely intervention.
Purpose of the Study:
- To determine if an intraocular pressure (IOP) stress test, specifically the water-drinking test (WDT), can identify glaucoma eyes at risk for faster progression.
- To evaluate the WDT's ability to detect progression risk in patients with apparently controlled office IOP.
Main Methods:
- A prospective cohort study involving 67 eyes of 36 glaucoma participants.
- Participants underwent a standardized water-drinking test (WDT) as an IOP stress test.
- Visual field (VF) and spectral-domain optical coherence tomography (SD-OCT) were used to assess functional and structural changes over time, with analyses adjusted for office IOP.
Main Results:
- Eyes with a WDT peak IOP greater than 21 mmHg showed significantly faster rates of mean deviation (MD) loss and retinal nerve fiber layer (RNFL) thinning.
- 37% of eyes with office IOP within target had a WDT peak IOP >21 mmHg, indicating a higher risk.
- The WDT identified 77% of fast-progressing eyes, whereas only 23% were above target based on office tonometry alone.
Conclusions:
- IOP stress testing, such as the WDT, is associated with faster functional and structural glaucoma progression.
- The WDT identified higher-risk eyes among those with apparently controlled office IOP.
- IOP stress testing provides complementary prognostic information to routine office tonometry for glaucoma management.
Related Concept Videos
Open Angle Glaucoma: Treatment
In open-angle glaucoma, the iridocorneal angle remains open, but the trabecular meshwork becomes stiff, slowing down the outflow of aqueous humor. This causes a buildup of aqueous humor in the anterior chamber, leading to a sudden increase in intraocular pressure. The treatment for open-angle glaucoma focuses on reducing the elevated intraocular pressure by either decreasing the secretion of aqueous humor or increasing its outflow.
Drugs such as carbonic anhydrase inhibitors, α2- and...
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
Angle Closure Glaucoma: Treatment
Angle-closure glaucoma, or closed-angle glaucoma, is an eye condition where the iris bulges out and blocks the iridocorneal angle, resulting in a buildup of aqueous humor and increased intraocular pressure. Immediate medical attention is necessary due to the sudden onset of symptoms. The treatment for angle-closure glaucoma includes short-term and long-term approaches. Short-term treatment involves using eye drops like pilocarpine to lower intraocular pressure by increasing aqueous humor...
Ophthalmic Drug Delivery Systems
Ophthalmic drug delivery faces major limitations due to poor absorption across the corneal membrane. This process is primarily driven by diffusion and is influenced by two main factors: the physicochemical properties of the drug and tear drainage. Most ophthalmic drugs, such as pilocarpine, epinephrine, atropine, and local anesthetics, are weak bases. They are typically formulated at an acidic pH to enhance chemical stability. However, this leads to high ionization, reducing their ability to...