Related Experiment Video
Updated: Feb 6, 2026

Quantification of the Abundance and Charging Levels of Transfer RNAs in Escherichia coli
Published on: August 22, 2017
Autonomous system for rapid field quantification of Escherichia coli in surface waters
D E Angelescu1, V Huynh1, A Hausot1
1Fluidion SAS, R&D Division, Paris, France.
Aims:
The purpose of this work is to present and evaluate the performance of a novel Automatic Lab-in-vial Escherichia coli Remote Tracking technology based on an automated real-time defined substrate approach, implemented in both portable and in situ instruments.
Methods And Results:
We present the fresh water calibration procedure, and assess performance using side-by-side comparison with most probable number (MPN) approaches in terms of accuracy, reproducibility and capability to correctly generate early-warning alerts. Long-term data from an operational in situ deployment at a potential bathing site is presented as well.
Conclusions:
Automatic Lab-in-vial Escherichia coli Remote Tracking technology is shown to be an accurate and rapid bacterial quantification technology, capable of autonomous in situ measurements with metrological capabilities comparable to those of an approved laboratory using MPN microplate techniques.
Significance And Impact Of The Study:
Rapid quantification of bacterial pollution is a requirement in water quality applications ranging from recreational water use, agriculture and aquaculture to drinking and wastewater treatment. The method and instruments presented in this work should enable fast and accurate bacterial concentration measurements to be performed in a portable or in situ manner, thus simplifying operational logistics, reducing time-to-result delays, and eliminating sample transportation constraints associated with traditional techniques.
More Related Videos
07:10Rapid Protocol for Preparation of Electrocompetent Escherichia coli and Vibrio cholerae
Published on: October 8, 2013
14:12Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Related Concept Videos
Equipotential Surfaces and Field Lines
Electric Field at the Surface of a Conductor
In the 19th century, Michael Faraday conducted the famous ice pail experiment to prove that the charges always reside on the surface of a conductor. The experimental set-up consists of a conducting uncharged container mounted on an insulating stand. The outer surface of the container is...
Autonomic Nervous System
The ANS comprises two main divisions: the sympathetic and parasympathetic divisions. These divisions function antagonistically to maintain a dynamic...
Autonomic Nervous System: Overview
Disorders of the Autonomic Nervous System
Raynaud's disease, also known as Raynaud's...
The Water Cycle