Related Experiment Video
Updated: Feb 6, 2026

Sequencing of mRNA from Whole Blood using Nanopore Sequencing
Published on: June 3, 2019
Sequencing nothing: Exploring failure modes of nanopore sensing and implications for life detection
Alexandra Pontefract1, Julie Hachey2, Maria T Zuber3
1Department of Molecular Biology, Massachusetts General Hospital, Boston, MA 02114, United States; Department of Earth, Atmospheric and Planetary Sciences, Massachusetts Institute of Technology, Cambridge, MA 02139, United States.
Abstract:
The detection of extant life is a major focus of many planned future planetary missions, a current challenge of which is the ability to target biomarkers capable of providing unambiguous evidence of life. DNA sequencing is increasingly recognized as a powerful tool for life detection for planetary exploration missions; beyond use of sequence information to determine the origins of the sample (e.g., extant life or forward contamination), recent advances in the field have enabled interrogation of single molecules, with or without amplification. The focus of this work is on failure modes, specifically the issues encountered when there is no-to-low input DNA into a sequencing device, and the potential for the generation of sequencing artifacts that could be interpreted as a false positive. Using Oxford Nanopore Technologies (ONT) MinION, we assess whether single molecule sequencing, involving no amplification, generates noise signals that could be misinterpreted in the context of a planetary exploration mission, and also whether the ability of the instrument to handle these types of situations could make it feasible for clean room monitoring. Utilizing quality score filtering techniques in place at the time of this experiment, runs containing only initial flowcell chemistry and/or library reagents generated 5 passing reads out of a total of 3568 measured reads, and contained estimated sequences with low complexity that did not map to the NCBI database. The noise characteristics in all instances suggest that quality thresholds were appropriately chosen by ONT: new chemistry and basecalling workflows have shown further suppression of noise sources, which completely mitigate the generation of spurious reads.
Related Concept Videos
Half-life of a Reaction
Characteristics of Life
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
The Tree of Life - Bacteria, Archaea, Eukaryotes
The Angiosperm Life Cycle
The Sense of Self: Reflected Self-Appraisal and Social Comparison