Endoscopic Bilateral Nipple-sparing Mastectomy via a Single Axillary Incision with Immediate Pre-pectoral Implant-based Breast Reconstruction
Published on: May 17, 2024
Is single-stage implant-based breast reconstruction (SSBR) with an acellular matrix safe?: Strattice™ or Meso
Nadine S Hillberg1, Patrick I Ferdinandus1, Rieky E G Dikmans2
11Department of Plastic, Reconstructive and Hand Surgery, Maastricht University Medical Centre, Maastricht, The Netherlands.
Background:
Acellular matrices (AM) might enable a direct single-stage breast reconstruction procedure resulting in an improved efficacy of the reconstruction phase for patients. Safety concerns are an important issue due to a recent study which shows that single-stage breast reconstruction with Strattice™ resulted in more complications versus a two-stage reconstruction. Therefore, the goal of this study is to compare the short- and long-term complications of a single-stage breast reconstruction with the use of two types of AM (Strattice™ and Meso Biomatrix®) versus two-stage breast reconstruction without the use of an AM.
Methods:
Cohort study with single-stage breast reconstruction with Strattice™ (n = 28) or Meso BioMatrix® (n = 20) or two-stage breast reconstruction without an AM (n = 36) at the Maastricht Academic Hospital, the Netherlands. All complications, in particular major complications with the need for re-admission to the hospital, re-exploration, and implant explantation, were the primary outcome measures. A 1-year follow-up was achieved for all patients.
Results:
Baseline characteristics of all 52 patients were similar between groups. There was a significantly higher complication rate in the single-stage AM groups with loss of the implant in 40.0% of the breasts from the Meso BioMatrix® group and in 10.7% of the Strattice™ group compared to no implant loss in the control group.
Conclusions:
This cohort study clearly suggests that the use of a single-stage breast reconstruction is not safe with the use of these AMs. Well-designed prospective studies that guarantee the safety of those matrices should be published before these AMs are used in implant-based surgery.Level of Evidence: Level III, risk / prognostic study.
Related Concept Videos
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
The Extracellular Matrix
The Extracellular Matrix
In order to maintain tissue organization, many animal cells are surrounded by structural molecules that make up the extracellular matrix (ECM). Together, the molecules in the ECM maintain the structural integrity of tissue as well as the remarkable specific properties of certain tissues.
Composition of the Extracellular Matrix
The extracellular matrix (ECM) is commonly composed of ground substance, a gel-like fluid, fibrous components, and many structurally and functionally diverse...
Stages of Infection
Stages of General Anesthesia