Measurement of 68Ga-DOTATOC Uptake in the Thoracic Aorta and Its Correlation with Cardiovascular Risk
Reeree Lee1, Jihyun Kim1, Jin Chul Paeng1
1Department of Nuclear Medicine, Seoul National University Hospital, 101 Daehak-ro, Jongno-gu, Seoul, 03080 South Korea.
Purpose:
68Ga-labeled 1,4,7,10-tetraazacyclododecane-N,N',N″,N‴-tetraacetic acid-d-Phe1-Tyr3-octreotide (68Ga-DOTATOC) is taken up by activated macrophages, which accumulate in active inflammatory lesions. The purpose of this study was to investigate the feasibility of 68Ga-DOTATOC PET/CT for assessment of vulnerable plaque, by evaluating correlation between aortic uptake of 68Ga-DOTATOC and cardiovascular risk factors.
Methods:
Fifty patients with neuroendocrine tumors who underwent 68Ga-DOTATOC PET/CT were retrospectively enrolled. The uptakes in the thoracic aorta were measured by two methods: multi-sample region-of-interest (ROI) method and single volume-of-interest (VOI) method. TBRmax-avg, TBRmean-avg, TBRmax-VOI, and TBRmean-VOI were defined by maximum and mean target-to-background ratio (TBR) from the multi-sample ROI method and the single VOI method, respectively.
Results:
Framingham risk score (FRS) exhibited significant correlations with TBRmax-avg and TBRmean-avg, as well as TBRmax-VOI (r = 0.3389-0.4593, P < 0.05 for all). TBRmax-avg and TBRmax-VOI were significantly higher in high FRS group than in low FRS group (1.48 ± 0.21 vs. 1.70 ± 0.17, P < 0.001 for TBRmax-avg and 1.90 ± 0.33 vs. 2.25 ± 0.36, P = 0.002 for TBRmax-VOI). TBR exhibited high correlations between the two measuring methods (r = 0.9684, P < 0.001 for TBRmean-avg and TBRmean-VOI and r = 0.8681, P < 0.001 for TBRmax-avg and TBRmax-VOI).
Conclusions:
68Ga-DOTATOC uptake in the thoracic aorta exhibited a significant correlation with cardiovascular risk factors, which suggests the feasibility of 68Ga-DOTATOC PET for vulnerable plaque imaging, with a simple measurement of the single VOI method that is comparable to the multi-sample ROI-based approach.
More Related Videos
07:25Isolation and Excision of Murine Aorta; A Versatile Technique in the Study of Cardiovascular Disease
Published on: November 24, 2014
09:47Measurement of Endothelium-Dependent Vasorelaxation in the Mouse Thoracic Aorta Using Tensometric Small Volume Chamber Myography
Published on: August 12, 2022
Related Concept Videos
Thoracic Aorta
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
The Aorta
The average diameter of the aorta is approximately 2-3 cm, but the size can vary depending on the section of the aorta and the individual's age, sex, and body size. The aorta is...
The Arch of Aorta
Encircling the heart, the coronary arteries form a ring-like structure before...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if: