Feasibility of A Novel On-Site Detection Method for Aflatoxin in Maize Flour from Markets and Selected Households in
Alex Paul Wacoo1,2,3, Deborah Wendiro4, Sarah Nanyonga5
1Department of Molecular Cell Biology, VU University Amsterdam, De Boelelaan 1108, 1081 HZ Amsterdam, The Netherlands. wacooalex@gmail.com.
Abstract:
In sub-Saharan Africa, there is a high demand for affordable and accessible methods for on-site detection of aflatoxins for appropriate food safety management. In this study, we validated an electrochemical immunosensor device by the on-site detection of 60 maize flour samples from six markets and 72 samples from households in Kampala. The immunosensor was successfully validated with a linear range from 0.7 ± 0.1 to 11 ± 0.3 µg/kg and limit of detection (LOD) of 0.7 µg/kg. The maize flour samples from the markets had a mean total aflatoxin concentration of 7.6 ± 2.3 µg/kg with approximately 20% of the samples higher than 10 µg/kg, which is the maximum acceptable level in East Africa. Further down the distribution chain, at the household level, approximately 45% of the total number contained total aflatoxin levels higher than the acceptable limit. The on-site detection method correlated well with the established laboratory-based HPLC and ELISA-detection methods for aflatoxin B₁ with the correlation coefficients of 0.94 and 0.98, respectively. This study shows the feasibility of a novel on-site detection method and articulates the severity of aflatoxin contamination in Uganda.
More Related Videos
06:11Author Spotlight: Improved Methods for Preparing Transverse Sections and Unrolled Whole Mounts of Maize Leaf Primordia for Fluorescence and Confocal Imaging
Published on: September 22, 2023
09:44RNAi-mediated Control of Aflatoxins in Peanut: Method to Analyze Mycotoxin Production and Transgene Expression in the Peanut/Aspergillus Pathosystem
Published on: December 21, 2015
Related Concept Videos
Household Wiring And Electrical Safety
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
What is Natural Selection?
Antibiotic Selection
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Types of Selection