Assessment of artefacts produced by metal posts on CBCT images
A P Lira de Farias Freitas1, Y W Cavalcanti2, F C M Costa1
1Department of Dentistry, State University of Paraíba, Campina Grande, PB, Brazil.
Aim:
To evaluate artefact intensity in cone beam computed tomography (CBCT) images of two alloys used in metal posts scanned using different exposure parameters.
Methodology:
The sample consisted of 20 single-rooted teeth divided into two groups for use with either a NiCr post or AgPd post. All teeth were scanned with and without their corresponding metal posts and with and without the presence of an extra restored tooth in the arch. The samples were scanned using CS 9000 3D scanner with two exposure protocols: 85 kV 6.3 mA and 85 kV 10 mA. Voxel size and FOV were fixed at 0.100 mm and 5 cm × 3.75 cm. The presence of artefacts was assessed qualitatively by two calibrated observers using the CBCT volume and paired 2D images, and quantitatively by one trained observer, using ImageJ software. Wilcoxon's signed rank, Mann-Whitney, kappa and chi-square tests were used for qualitative analyses. Two-way anova and Tukey's tests were used for quantitative analyses. All analyses were conducted considering the 95% confidence level (α < 0.05).
Results:
For the CBCT volume qualitative analysis, significant differences were observed between the metal alloys in the presence of an extra restored tooth, with higher artefact intensity for AgPd when assessing hypodense halos and lines (P = 0.006). Images with two restored teeth had significantly more hypodense and hyperdense lines (P = 0.033). When evaluating exposure parameters and number of restored teeth, the paired image quality analysis revealed significant disagreement between observers for diagnostic image quality (P = 0.001). Quantitative artefact analysis revealed higher artefact intensity for the AgPd posts in the presence of two restored teeth.
Conclusion:
Although the exposure parameters tested did not interfere with artefact intensity, post alloys with a higher atomic number and the presence of another metal structure in the arch increased artefact intensity and impaired the diagnostic quality of CBCT images.
More Related Videos
04:51Author Spotlight: Functionalizing Metal-Organic Frameworks: Advancements, Challenges, and the Power of Post-Synthetic Ligand Exchange
Published on: June 23, 2023
09:05Imaging Metals in Brain Tissue by Laser Ablation - Inductively Coupled Plasma - Mass Spectrometry LA-ICP-MS
Published on: January 22, 2017
Related Concept Videos
Alkali Metals
Table 1: Properties of the alkali metals
Bonding in Metals
Metallic Solids
All metallic solids exhibit high thermal and electrical conductivity, metallic luster, and malleability....
Metal-Ligand Bonds
In these complexes, transition metals form coordinate covalent bonds, a kind of Lewis acid-base interaction in which both of the electrons in the bond are contributed by a donor (Lewis base) to an electron acceptor (Lewis acid). The Lewis acid in...
Properties of Transition Metals
Theory of Metallic Conduction
In this theory, Newton's second law of motion is used to determine the acceleration of an electron in the presence of an applied electric field. Then, its velocity is expressed via this acceleration.
An electron moves through the crystal, containing positive ions,...