Related Experiment Video
Updated: Feb 6, 2026

Direct and Indirect Culture Methods for Studying Biodegradable Implant Materials In Vitro
Published on: April 15, 2022
Evaluation of positional accuracy in multiple implants using four different splinting materials: An in vitro study.
Thara Maria Joseph1, R Ravichandran1, S Lylajam1
1Department of Prosthodontics, Government Dental College, Trivandrum, Kerala, India.
Accurate dental implant prostheses require precise positioning. Flowable composite and bite registration paste are effective, cost-efficient splinting materials for multiple implant impressions, matching conventional materials in accuracy.
Area of Science:
- Dental Materials Science
- Prosthodontics
- Biomaterials Engineering
Background:
- Prosthesis misfit in implant restorations can lead to complications like screw loosening and fracture.
- Accurate impressions are crucial for passive fit and long-term success of implant prostheses.
- Splinting multiple implants with accurate materials is a viable option to improve impression accuracy.
Purpose of the Study:
- To evaluate the positional accuracy of multiple implants using different splinting materials.
- To compare the efficacy of acrylic resin, pattern resin, flowable composite, and bite registration paste for implant splinting.
Main Methods:
- Four implant analogs were placed in an acrylic resin model and splinted using four different materials: acrylic resin, pattern resin, flowable composite, and bite registration paste.
- Impressions were made using vinyl polysiloxane, and the positional accuracy of the analogs in the retrieved casts was analyzed.
- Statistical analysis included one-way ANOVA and confidence interval calculation to assess accuracy.
Main Results:
- All tested splinting materials demonstrated comparable accuracy in reproducing implant positions.
- No significant differences were found in the interimplant distances between the master model and the tested groups (P > 0.05).
- Flowable composite and bite registration paste showed accuracy on par with conventionally used pattern resin and acrylic resin.
Conclusions:
- Flowable composite and bite registration paste are recommended as suitable splinting materials for multiple implant impressions.
- These materials offer comparable accuracy to traditional splinting agents like pattern resin and acrylic resin.
- The use of flowable composite or bite registration paste can enhance the precision of multi-implant restorations.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Uncertainty in Measurement: Accuracy and Precision
Bioavailability Study Design: Single Versus Multiple Dose Studies
Position-effect Variegation
Accuracy and Precision