Related Experiment Video
Updated: Feb 6, 2026

Applications of EEG Neuroimaging Data: Event-related Potentials, Spectral Power, and Multiscale Entropy
Published on: June 27, 2013
Frontal EEG Temporal and Spectral Dynamics Similarity Analysis between Propofol and Desflurane Induced Anesthesia
Quan Liu1, Li Ma1, Shou-Zen Fan2
1School of Information Engineering, Wuhan University of Technology, Wuhan 430070, Hubei, China.
Abstract:
Electroencephalogram (EEG) signal analysis is commonly employed to extract information on the brain dynamics. It mainly targets brain status and communication, thus providing potential to trace differences in the brain's activity under different anesthetics. In this article, two kinds of gamma-amino butyric acid (type A -GABAA) dependent anesthetic agents, propofol and desflurane (28 and 23 patients), were studied and compared with respect to EEG spectrogram dynamics. Hilbert-Huang Transform (HHT) was employed to compute the time varying spectrum for different anesthetic levels in comparison with Fourier based method. Results show that the HHT method generates consistent band power (slow and alpha) dominance pattern as Fourier method does, but exhibits higher concentrated power distribution within each frequency band than the Fourier method during both drugs induced unconsciousness. HHT also finds slow and theta bands peak frequency with better convergence by standard deviation (propofol-slow: 0.46 to 0.24; theta: 1.42 to 0.79; desflurane-slow: 0.30 to 0.25; theta: 1.42 to 0.98) and a shift to relatively lower values for alpha band (propofol: 9.94 Hz to 10.33 Hz, desflurane 8.44 Hz to 8.84 Hz) than Fourier one. For different stage comparisons, although HHT shows significant alpha power increases during unconsciousness stage as the Fourier did previously, it finds no significant high frequency (low gamma) band power difference in propofol whereas it does in desflurane. In addition, when comparing the HHT results within two groups during unconsciousness, high beta band power in propofol is significantly larger than that of desflurane while delta band power behaves oppositely. In conclusion, this study convincingly shows that EEG analyzed here considerably differs between the HHT and Fourier method.
More Related Videos
11:28Concurrent EEG and Functional MRI Recording and Integration Analysis for Dynamic Cortical Activity Imaging
Published on: June 30, 2018
08:45Mapping Cortical Dynamics Using Simultaneous MEG/EEG and Anatomically-constrained Minimum-norm Estimates: an Auditory Attention Example
Published on: October 24, 2012
Related Concept Videos
Causes of Similarity-Dissimilarity Effect
Bacterial Transformation
Griffith made an unexpected discovery when he killed the pathogenic strain and mixed its remains with the live, non-pathogenic strain. Not only did the mixture kill host mice, but it also contained living pathogenic bacteria that...
Factors Influencing Attraction III: Similarity
General Anesthesia: Overview
General anesthesia induces unconsciousness in the whole body, while the others target specific areas or sensations. It is administered to minimize adverse effects, maintain...
Stages of General Anesthesia
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...