Related Experiment Video
Updated: Feb 6, 2026

Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots
Published on: May 21, 2017
Aortic valve construction using pericardial tissue: short-term single-centre outcomes
Fanar Mourad1, Sharaf-Eldin Shehada1, Juri Lubarski1
1Department of Thoracic and Cardiovascular Surgery, West German Heart and Vascular Centre, University Hospital Essen, Essen, Germany.
Objectives:
Aortic valve construction using pericardial tissue has been known since the late 1960s. The procedure was re-introduced by Ozaki in 2010 and is currently used to treat specific aortic valve diseases. The exact sizing of the neo-cusps and the insertion of the commissures remain the keys to success when performing this procedure. We evaluated our experience using modified custom-made templates.
Methods:
In this prospective single-centre study, we evaluated 52 consecutive patients who underwent aortic valve construction between September 2015 and March 2017 using either autologous (16 patients, 30.8%) or tissue-engineered pericardium (36 patients, 69.2%). Most patients (34, 65.4%) presented with aortic stenosis or endocarditis (5, 9.6%). Twenty patients had bicuspid and 5 had unicuspid valves. A modified sizing technique with specially designed templates was used. The primary end point was early death; the secondary end points were major adverse cardiac and cerebrovascular events, freedom from reoperation and overall mortality rate. Echocardiographic follow-up was performed intraoperatively and at 12-month intervals.
Results:
The mean age was 60 ± 14 years; 63.5% were men; and 34 (65.4%) patients had combined procedures. The mean cross-clamp time was 99 ± 17 min. Early outcomes included 1 stroke, 2 patients needing short-term dialysis and 1 death. During follow-up (mean 11.2 ± 4.8 months), trace aortic regurgitation was observed in 4 patients; the mean pressure gradient was 6.8 ± 2.9 mmHg. Three patients died later (of non-cardiac reasons), and 5 patients needed reoperation due to endocarditis.
Conclusions:
Aortic valve construction using pericardial tissue could be an alternative in middle-age patients presenting with aortic valve disease in whom valve repair was not possible. The newly designed templates allow exact sizing of the neo-cusps and optimal commissure implantation; however, long-term follow-up in a larger cohort is warranted to assess the durability of the neo-valves.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Predicting Reaction Outcomes
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Long-term Depression
Guidelines for Writing Outcome
Patient outcomes reflect the patient's response to the goal rather than what the nurse aims to achieve. Terminology should be observable and measurable to avoid the reader's interpretation. The desired outcome should be realistic and achievable in the designated care timeframe. Expected outcomes should align with adjunctive therapies. The outcome should enhance care...
Short-distance Transport of Resources

