Mesocosm-Scale Constructed Wetland Design for Wastewater Treatment
Published on: May 2, 2025
Lessons learnt from a pilot study on residual dye removal by an aerated treatment wetland
F Masi1, A Rizzo1, R Bresciani1
1Iridra Srl, Via La Marmora 51, 50121 Florence, Italy.
Abstract:
Treatment wetlands (TWs) have shown good capacity in dye removal from textile wastewater. However, the high hydraulic retention times (HRTs) required by these solutions and the connected high area requirements, remain a big drawback towards the application of TWs for dye treatment at full scale. Aerated TWs are interesting intensified solutions that attempt to reduce the TW required area. Therefore, an aerated CW pilot plant, composed of a 20 m2 horizontal subsurface flow TW (HF) and a 21 m2 Free Water System (FWS), equipped with aeration pipelines, was built and monitored to investigate the potential reduction of required area for dye removal from the effluent wastewater of a centralized wastewater treatment plant (WWTP). During a 8 months long study, experimenting with different hydraulic retention times (HRTs - 1.2, 2.6 and 3.5 days) and aeration modes (intermittent and continuous), the pilot plant has shown a normal biological degradation for organic matter and nutrients, while the residual dye removal has been very low, as demonstrated by the absorbance measure at three wavelengths: at 426 nm (blue) the removal varies from -55% at influent absorbance of 0.010 to 41% at 0.060; at 558 nm (yellow) the removal is negative at 0.005 (-58%) and high at higher influent concentrations (72% at 0.035 of absorbance for the inlet); at 660 nm (red) -82% of removal efficiency was obtained at influent absorbance of 0.002 and 74% at 0.010. These results are a consequence of the biological oxidation processes taking place in the WWTP, so that the residual dye seems to be resistant to further aerobic degradation. Therefore, TWs enhanced by aeration can provide only a buffer effect on peak dye concentrations.
Related Concept Videos
Residual Plots
When the residual values are plotted against the variable x, it is called a residual...
Residual Stresses
Pilot and Numeric Relaying
Residual Stresses in Circular Shafts
Residual Stresses in Bending
Residuals and Least-Squares Property
If the observed data point lies above the line, the residual is positive, and the line underestimates the actual data value for y. If the observed data point lies below the line, the residual is negative, and the line overestimates the actual data value for y.
The process of fitting the best-fit...