Related Experiment Video
Updated: Feb 6, 2026

A Spin-Tip Enrichment Strategy for Simultaneous Analysis of N-Glycopeptides and Phosphopeptides from Human Pancreatic Tissues
Published on: May 4, 2022
Assessing the reproducibility of an O-glycopeptide enrichment method with a novel software, Pinnacle
Adam Pap1,2, Amol Prakash3, Katalin F Medzihradszky1
1Laboratory of Proteomics Research, Biological Research Centre, Hungarian Academy of Sciences, Szeged, Hungary.
Abstract:
A novel software, Pinnacle was used to reassess the reproducibility of a 2-step lectin-based O-glycopeptide enrichment method. A publicly available dataset consisting of 12 data files representing 3 technical replicates of enriched glycopeptides from human serum was investigated. Previously, an attempt for reproducibility assessment was made utilizing an MS/MS scan (MS2)-based method. However, the stochastic nature of precursor ion selection strongly biased this approach leading to underestimated rate of reproducibility. To bypass this problem, our present method follows the general path to confidently identify O-glycopeptides (database search with MS/MS data) supplemented with full scan/survey scan (MS1)/extracted ion chromatogram (XIC) mining in all files using two software packages, Pinnacle and Skyline. Confident MS/MS identifications were delivered by Protein Prospector. With this input Skyline indicated a 70% reproducibility for our workflow. However, Pinnacle performed better, indicating the presence of 90% of the confidently assigned glycopeptides in all the three replicates. Pinnacle, just like Skyline, performs ion extraction using the high accuracy, high resolution mass measurement data but it also utilizes all the available MS/MS spectra, even from different activation methods, within the same file to make mass spectrometric data evaluation for glycopeptides more reliable.
Related Concept Videos
Statistical Software for Data Analysis and Clinical Trials
GIS Software, Hardware, and Sources of GIS Data
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Assessment of the Mouth
Mouth Inspection
The inspection begins with visually examining the mouth for symmetry, color, and size.
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...

