Related Experiment Video
Updated: Feb 6, 2026

Quantum State Engineering of Light with Continuous-wave Optical Parametric Oscillators
Published on: May 30, 2014
Stabilization of self-mode-locked QDash lasers subject to simultaneous continuous-wave optical injection and optical
Abstract:
In this paper, we report stabilization of self-mode-locked two-section quantum-dash lasers on the widest range of delay using simultaneous optical injection and optical feedback. With continuous-wave optical injection, various wavelengths spanning a range from 1568 to 1578 nm were investigated and optimum wavelengths (1571.210 to 1572.710) yielding the narrowest RF linewidth and reduced timing jitter of slave laser were identified. In addition, the dependence of RF linewidth and pulse repetition rate on injected wavelength was further explored. Our results indicate that simultaneous optical feedback and optical injection significantly improves the RF linewidth across the widest delay range compared to optical feedback alone. Under fully resonant feedback and optimum injection parameters, a minimum RF linewidth of 1 kHz (instrument limited) was achieved with simultaneous optical injection plus optical feedback, which was >2× lower than optical feedback alone and more than 100× lower than free-running. This stabilization technique is implemented in an all-optical arrangement without optical/electrical conversion, which is ideal for high-repetition-rate devices and photonic integration.
More Related Videos
14:18Automation of Mode Locking in a Nonlinear Polarization Rotation Fiber Laser through Output Polarization Measurements
Published on: February 28, 2016
08:48Low-cost Custom Fabrication and Mode-locked Operation of an All-normal-dispersion Femtosecond Fiber Laser for Multiphoton Microscopy
Published on: November 22, 2019
Related Concept Videos
Modes of Standing Waves - I
Modes of Standing Waves: II
For a tube open at one end and closed at the other filled with air, the modes are such that there is always an antinode at the open end and a node at the closed end....
Feedback Inhibition
BIBO stability of continuous and discrete -time systems
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
Properties of Enantiomers and Optical Activity
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...