Related Experiment Video
Updated: Feb 6, 2026

Protocol for Biofilm Streamer Formation in a Microfluidic Device with Micro-pillars
Published on: August 20, 2014
Clogging-free continuous operation with whole blood in a radial pillar device (RAPID)
Ninad Mehendale1, Oshin Sharma1, Shilpi Pandey1
1Department of Biosciences and Bioengineering, Indian Institute of Technology Bombay, Powai, Mumbai, 400076, India.
Abstract:
Pillar-based passive microfluidic devices combine the advantages of simple designs, small device footprint, and high selectivity for size-based separation of blood cells. Most of these device designs have been validated with dilute blood samples. Handling whole blood in pillar-based devices is extremely challenging due to clogging. The high proportion of cells (particularly red blood cells) in blood, the varying sizes and stiffness of the different blood cells, and the tendency of the cells to aggregate lead to clogging of the pillars within a short period. We recently reported a ra dial pi llar d evice (RAPID) design for continuous and high throughput separation of multi-sized rigid polystyrene particles in a single experiment. In the current manuscript, we have given detailed guidelines to modify the design of RAPID for any application with deformable objects (e.g. cells). We have adapted RAPID to work with whole blood without any pre-processing steps. We were successful in operating the device with whole blood for almost 6 h, which is difficult to achieve with most pillar-based devices. The availability of multiple parallel paths for the cells and the provision for a self-generating cross flow in the device design were the main reasons behind the minimal clogging in our device. We also observed that a vibrator motor attached to the inlet tubing occasionally disturbed the cell clumps. As an illustration of the improved device design, we demonstrated up to ∼ 60-fold enrichment of platelets.
More Related Videos
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Operational Amplifiers
Real Number Operations
Continuing Care

