Related Experiment Video
Updated: Feb 6, 2026

Fetal Echocardiography and Pulsed-wave Doppler Ultrasound in a Rabbit Model of Intrauterine Growth Restriction
Published on: June 29, 2013
Pulmonary Vein Flow Impedance: An Early Predictor of Cardiac Dysfunction in Intrauterine Growth Restriction
Nathalie J M Bravo-Valenzuela1,2, Paulo Zielinsky3, Jesús Zurita-Peralta1
1Fetal Cardiology Unit, Institute of Cardiology, Porto Alegre, Brazil.
Introduction:
In intrauterine growth restriction (IUGR), increased uteroplacental vascular impedance contributes to preferential flow to left ventricle (LV), with consequent alteration of its compliance and increased left atrial (LA) pressure. Pulmonary vein pulsatility index (PVPI) reflects the increased impedance to LA filling and could be used as a cardiac monitoring parameter in IUGR.
Material And Methods:
A total of 27 IUGR fetuses (group 1), 28 fetuses with appropriate growth for gestational age from hypertensive mothers (group 2), and 28 controls (group 3) were studied. Pulsatility indices (PIs) of pulmonary veins and ductus venosus were calculated by Doppler echocardiography. Obstetric ultrasound was used to assess the PIs of uterine, umbilical, and middle cerebral arteries. Statistical analysis used analysis of variance, post-hoc Tukey, and Pearson's tests.
Results:
Mean PVPI was higher in IUGR group (1.27 ± 0.39) when compared to groups 2 (1.02 ± 0.37; p = 0.01) and 3 (0.75 ± 0.12; p < 0.001). In group 2, moderate correlation between PVPI and ductus venosus pulsatility index (DVPI) was found but not between PVPI and cerebroplacental ratio (CPR).
Discussion:
Higher PVPI in IUGR reflects decreased LV compliance and altered LA dynamics. As LV dysfunction precedes right ventricle, our results suggest that PVPI could be an early echocardiographic parameter of fetal diastolic function in IUGR.
Related Concept Videos
Restriction Enzymes
The host bacteria protect their own genomic DNA from these enzymes by methylating these sites. Some...
Impedance Combination
Impedances and Admittance
Impedance is a measure of resistance to sinusoidal current flow in an AC circuit. Unlike their behavior in DC circuits, where inductors appear as short circuits and capacitors as open circuits, the behavior of these components in AC...
Veins
Structure of Veins:
The structure of veins is specifically designed to assist in the low-pressure transportation of...
Gene Flow
Series Impedances: Three-Phase Line
Using Kirchhoff's laws, an integro-differential equation for the network is derived. This equation accounts for unbalanced phase currents, which may induce return currents through neutral wires and the earth, seeking the least impedance path. Earth return conductors can replace the...

