Mitral Valve Compression Induced Hypoxemia After Left Ventricular Assist Device Surgery: A Case Report
Hisham Hosny1,2, Hesham Hassan3, Nicholas Lees4
1From the Department of Anaesthesia and Critical Care, Royal Brompton Hospital, London, United Kingdom.
Abstract:
Blood flow obstruction of left ventricular assist device (LVAD) is not uncommon. Causes of flow obstructions could be prepump, intrapump, and postpump. Clinical and echocardiographic parameters of LVAD obstruction vary substantially, ranging from being completely asymptomatic with unchanged functional status, normal filling pressures to frank cardiogenic shock. In the current case report, we present hypoxemia as an early presentation of LVAD inflow obstruction in the early postimplantation period in the absence of respiratory cause for hypoxemia.
More Related Videos
Related Concept Videos
Mitral Valve Prolapse I: Introduction
Mitral Valve Prolapse II: Assessment and Management
Mitral Valve Prolapse III: Nursing Management
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...