Related Experiment Video
Updated: Feb 6, 2026

Cellular Lipid Extraction for Targeted Stable Isotope Dilution Liquid Chromatography-Mass Spectrometry Analysis
Published on: November 17, 2011
[Determination of 20 polychlorinated biphenyls in fish samples by gas chromatography-triple-quadrupole mass
Yanping Cao1, Dafeng Jiang1, Fenghua Li1
1Shandong Center for Disease Control and Prevention, Jinan 250014, China.
Abstract:
An improved method based on the isotope dilution technique was developed for the determination of 20 polychlorinated biphenyls (PCBs) in fish samples, including seven indicator polychlorinated biphenyls. The analysis was performed by gas chromatography-triple-quadrupole mass spectrometry (GC-MS/MS) in the multiple reaction monitoring (MRM) mode. Two MRM transitions were monitored for each PCB congener for quantitation and qualification purposes. The edible parts of the fish samples were shattered, frozen, and dried. 13C-PCB surrogate standards were spiked into the fish samples. The PCBs in fish samples and the surrogate standards were extracted by auto-Soxhlet extraction. The extract was cleaned-up by a disposable multi-layer column packed with acidic silica gel and basic alumina. 13C-PCB recovery standards were spiked into the extract before injection. The separation was performed on a TG-5MS capillary column. Quantitation was performed by the internal standard method. Every group of PCBs used a same number chlorinated 13C-isotope PCBs congener as the internal standard. The calibration curves of 20 PCB congeners were linear (correlation coefficient (r)>0.99) within the range of 0.05-10 μg/L. For the recovery test, three levels were spiked in matrices. The average recoveries obtained by this method were 80.3%-117.6% and the relative standard deviations (RSDs, n=6) were 5.09%-18.5%. The limits of determination (LODs) were 0.01-0.02 μg/kg. Contents of the 20 PCBs in the fish samples were in the range 1.2-8.8 μg/kg (wet weight), while those of the seven indicator PCBs were in the range 0.68-6.4 μg/kg (wet weight). The method is suitable for determining polychlorinated biphenyls in fish samples.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Isotope Effect
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Isotopes
An element's atomic mass, or weight,...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Atomic Mass

