Related Experiment Video
Updated: Feb 6, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Influence of Shrinkage and Viscosity of Flowable Composite Liners on Cervical Microleakage of Class II Restorations:
Abstract:
This study determined the influence of shrinkage and viscosity of flowable composite liners on the cervical microleakage of Class II restorations using micro-CT. Seven composites of varying viscosities were selected and included five giomers (Shofu Beautifil II [BF], Flow Plus F00 and F03 [F00 and F03], Flow F02 and F10 [F02 and F10]) and 2 nano-filled composites (3M-ESPE Filtek Z350 [Z350] and Filtek Z350 Flowable [Z350F]). Polymerization shrinkage (n=7) was assessed with the Acuvol volumetric shrinkage analyzer while complex viscosity was determined with the advanced rheometric expansion system at 25°C. Standardized Class II restorations incorporating 1-mm horizontal layers of different flowable liners and 3-mm oblique layers of BF or Z350 were subjected to a silver nitrate test for 24 hours and examined using micro-CT. Microleakage was determined at 0.1-mm intervals from the buccal to lingual surfaces providing 30 sites per specimen and scored accordingly. Statistical analysis was performed with the one-way ANOVA, Kruskal-Wallis test, and Spearman's rho correlation at a significance level of p<0.05. Mean volumetric shrinkage ranged from 5.33±0.17% to 2.35±0.02% for F02 to Z350, respectively. The flowable materials had significantly higher shrinkage than did their sculptable counterparts (BF and Z350). Complex viscosities ranged from 9.65 to 4.20 (Z350 and F10, respectively) at a frequency of 10 rad/s and from 8.16 to 3.28 (Z350 and F03, respectively) for 100 rad/s. Giomer restorations had significantly less leakage than did those restored with nano-filled composites. No microleakage was observed with restorations lined with F02 or F10. The use of flowable liners reduced cervical microleakage of Class II restorations. Interfacial integrity of Class II restorations was significantly correlated with liner viscosity, filler volume, and shrinkage.
More Related Videos
Related Concept Videos
Surface Tension, Capillary Action, and Viscosity
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
Viscosity
The SI unit of viscosity is...
Restorative Care
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...

