Related Experiment Video
Updated: Feb 6, 2026

Mobile Game-based Virtual Reality Program for Upper Extremity Stroke Rehabilitation
Published on: March 8, 2018
Validation of a Kinect V2 based rehabilitation game
Mengxuan Ma1, Rachel Proffitt2, Marjorie Skubic1
1Department of Electrical Engineering and Computer Science, University of Missouri, Columbia, MO, United States of America.
Abstract:
Interactive technologies are beneficial to stroke recovery as rehabilitation interventions; however, they lack evidence for use as assessment tools. Mystic Isle is a multi-planar full-body rehabilitation game developed using the Microsoft Kinect® V2. It aims to help stroke patients improve their motor function and daily activity performance and to assess the motions of the players. It is important that the assessment results generated from Mystic Isle are accurate. The Kinect V2 has been validated for tracking lower limbs and calculating gait-specific parameters. However, few studies have validated the accuracy of the Kinect® V2 skeleton model in upper-body movements. In this paper, we evaluated the spatial accuracy and measurement validity of a Kinect-based game Mystic Isle in comparison to a gold-standard optical motion capture system, the Vicon system. Thirty participants completed six trials in sitting and standing. Game data from the Kinect sensor and the Vicon system were recorded simultaneously, then filtered and sample rate synchronized. The spatial accuracy was evaluated using Pearson's r correlation coefficient, signal to noise ratio (SNR) and 3D distance difference. Each arm-joint signal had an average correlation coefficient above 0.9 and a SNR above 5. The hip joints data had less stability and a large variation in SNR. Also, the mean 3D distance difference of joints were less than 10 centimeters. For measurement validity, the accuracy was evaluated using mean and standard error of the difference, percentage error, Pearson's r correlation coefficient and intra-class correlation (ICC). Average errors of maximum hand extent of reach were less than 5% and the average errors of mean and maximum velocities were about 10% and less than 5%, respectively. We have demonstrated that Mystic Isle provides accurate measurement and assessment of movement relative to the Vicon system.
Related Concept Videos
Reliability and Validity
Social Foundations of Self I: Play and Game
Data Validation
Key parameters for method validation include:
Data Validation
Nursing assessment guides are generally based on holistic models rather than medical...
Formulating and Validating Nursing Diagnosis I
There are thirteen domains...
Formulating and Validating Nursing Diagnosis II
Risk nursing diagnoses represent clinical judgments of an individual, family, or community more vulnerable to developing the health problem than others...

