Related Experiment Video
Updated: Feb 6, 2026

A Murine Model of Stent Implantation in the Carotid Artery for the Study of Restenosis
Published on: May 14, 2013
Optical coherence tomographic analysis of drug-eluting in-stent restenosis at different times: A STROBE compliant
Chunguang Feng1, Peiying Zhang, Bing Han
1Department of Cardiology Department of Imaging, Xuzhou Central Hospital in Jiangsu, Institute of Cardiovascular Disease, Xuzhou, China.
Abstract:
The imaging characteristics of drug-eluting in-stent restenosis (ISR) at different times varied; however, the mechanism had not yet been elucidated.To analyze the imaging characteristics of drug-eluting ISR at different time points by optical coherence tomography (OCT) and investigate the cause of the stent treatment failure.A total of 70 patients with drug-eluting ISR undergoing OCT were enrolled (intimal hyperplasia ≥50% of stent area) and implanted with drug-eluting stents. According to stent implantation time, the patients were divided into 2 groups: early in-stent restenosis group (E-ISR group) (group A, n = 35, stent age ≤12 months) and late in-stent restenosis group (L-ISR group) (group B, n = 35, stent age ≥24 months). A qualitative analysis of the restenosis tissue included the nature of restenosis tissue (homogeneous and heterogeneous), neoatherosclerosis, thin-cap fibroatheroma (TCFA), and microvessels.The ratio of ≥75% cross-sectional area stenosis between the L-ISR and E-ISR groups was (60.00% vs 34.28%, P < .05). The heterogeneous intima, neoatherosclerosis, TCFA, and microvessels were more prevalent in the L-ISR group as compared to the E-ISR group (71.43% vs 45.71%, P < .05; 48.57% vs 22.86%, P < .05; 25.71% vs 5.71%, P < .05; 22.86% vs 2.86%, P < .05, respectively).The morphological characteristics of L-ISR were significantly different from those in the E-ISR; the former was closer to the atherosclerotic plaque, which provided a new approach for the treatment of drug-eluting ISR.
Related Concept Videos
Time Course of Drug Effect
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
High-Performance Liquid Chromatography: Elution Process
Noncompartmental Analysis: Mean Residence Time
After the administration of a drug through intravenous bolus injection, the drug molecules are distributed throughout the body and remain there for varying periods. The MRT represents the average time these drug molecules stay in the...
Therapeutic Drug Monitoring: Drug Analysis Methods
Methods for Studying Drug Absorption: In vitro
The diffusion cell method uses a two-compartment cell, including a donor compartment with the drug solution, which simulates the environment where the drug is applied, and a receptor compartment with a buffer solution, which simulates the environment...