Knee extensor muscles strength indicates global lower-limb strength in individuals who have suffered a stroke: A
Larissa Tavares Aguiar1, Júlia Caetano Martins1, Sherindan Ayessa Ferreira de Brito1
1Department of Physical Therapy, Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, Minas Gerais, Brazil.
Objectives:
This study had three aims: (1) to evaluate the relationships between the paretic knee extensor muscle strength and global lower-limb strength in individuals who had suffered a sub-acute/chronic stroke, (2) to determine whether global lower-limb strength, sex, body mass index, or age could predict knee extensor muscle strength, and 3) to investigate whether the results obtained via a Modified Sphygmomanometer Test (MST) would be similar to those obtained using a hand-held dynamometer.
Methods:
This was a cross-sectional study, performed at a research laboratory, at participants' homes, or at outpatient clinics. Forty-two individuals with a sub-acute stroke and 45 individuals with a chronic stroke participated. Maximum isometric strength of the paretic lower-limb muscles (i.e. hip, knee, and ankle flexors/extensors, hip abductors) was measured using the MST and a hand-held dynamometer.
Results:
Significant and high correlation coefficients were found between knee extensor muscle strength and global lower-limb strength as measured by the combined strength values of 6 lower limb muscle groups in individuals with sub-acute (0.81≤r≤0.88; p<0.05) and chronic (0.82≤r≤0.85; p<0.05) stroke. Step-wise multiple regression analysis revealed that only global lower-limb strength was retained in the model and accounted for 66-78% and 67-72% (p<0.001) of the variance in knee extensor muscle strength at the sub-acute and chronic phases post-stroke, respectively. The results obtained via the MST were similar to those obtained using the hand-held dynamometer.
Conclusion:
Paretic knee extensor muscles strength, assessed using a MST or a hand-held dynamometer, indicates global lower-limb strength in individuals with a sub-acute or chronic stroke.
Related Concept Videos
Acid Strength and Molecular Structure
In the absence of any leveling effect, the acid strength of binary compounds of hydrogen with nonmetals (A) increases as the H-A bond strength decreases down a group in the periodic table. For group 17, the order of increasing acidity is HF < HCl < HBr < HI. Likewise, for group 16, the order of increasing acid strength is H2O < H2S < H2Se < H2Te. Across a row in the periodic table, the acid strength of binary hydrogen compounds increases with increasing...
Cross-Sectional Research
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Relation Between Tensile Strength and Compressive Strength of Concrete
The Equilibrium Binding Constant and Binding Strength
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...