A Single Input Multiple Output (SIMO) Variation-Tolerant Nanosensor
Dong-Il Moon, Beomseok Kim, Ricardo Peterson1
1Department of Aeronautics and Astronautics , Stanford University , Stanford , California 94305 United States.
Abstract:
Successful transition to commercialization and practical implementation of nanotechnology innovations may very well need device designs that are tolerant to the inherent variations and imperfections in all nanomaterials including carbon nanotubes, graphene, and others. As an example, a single-walled carbon nanotube network based gas sensor is promising for a wide range of applications such as environment, industry, and biomedical and wearable devices due to its high sensitivity, fast response, and low power consumption. However, a long-standing issue has been the production of extremely high purity semiconducting nanotubes, thereby contributing to the delay in the market adoption of those sensors. Inclusion of even less than 0.1% of metallic nanotubes, which is inevitable, is found to result in a significant deterioration of sensor-to-sensor uniformity. Acknowledging the coexistence of metallic and semiconducting nanotubes as well as all other possible imperfections, we herein present a novel variation-tolerant sensor design where the sensor response is defined by a statistical Gaussian measure in contrast to a traditional deterministic approach. The single input and multiple output data are attained using multiport electrodes fabricated over a relatively large area single nanotube ensemble. The data processing protocol discards outlier data points and the origin of the outliers is investigated. Both the experimental demonstration and complementary analytical modeling support the hypothesis that the statistical analysis of the device can strengthen the credibility of the sensor constructed using nanomaterials with any imperfections. The proposed strategy can also be applied to physical, radiation, and biosensors as well as other electronic devices.
Related Concept Videos
What is Variation?
The range, standard deviation, standard error, and variance are the different measures of variation.
Range: The range is the difference between its maximum and...
Variation
When independent and dependent variables are plotted on a scatter plot, the slope of a line is a value that describes the rate of change between the two...
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Variation: Normal Distribution, Range, and Standard Deviation
Conservative Site-specific Recombination and Phase Variation
The recognition sites for Cre recombinase called LoxP...