Related Experiment Video
Updated: Feb 6, 2026

Immunoglobulin G N-Glycan Analysis by Ultra-Performance Liquid Chromatography
Published on: January 18, 2020
Detection of C60 in environmental water using dispersive liquid-liquid micro-extraction followed by high-performance
Qiang Wang1, Lei Li1, Chen-Lu Long1
1Center for Environment and Water Resources, College of Chemistry and Chemical Engineering, Central South University, Changsha, People's Republic of China.
Abstract:
The wide application of fullerene C60 nanoparticles would inevitably lead to their release into the environment. In order to evaluate the environment risks of C60 and the subsequent effects on ecosystem health, a reliable quantitative methodology of C60 should be established. In this study, a rapid pretreatment method called low-density solvent-based dispersive liquid-liquid micro-extraction (DLLME) combined high-performance liquid chromatography-UV detector (HPLC-UV) was developed to detect C60 in environmental water. In this proposed method, toluene and methanol were chosen as the extraction solvent and the dispersive solvent, respectively. The optimized volume of extraction solvent and dispersive solvent were 100 μL and 10 μL, respectively. And the best shaking time was chosen as 10 min at room temperature for the optimal homogenization procedure for the extraction of C60 in water samples. The enrichment factor of 50 was obtained with 100 μL toluene, and the recoveries of C60 from various environmental samples were in the range of 81.4 ± 5.0-101.4 ± 6.2% at 1.25-5.00 µg/L spiked levels. The detection limits of C60 in tap water, surface water, living sewage and mining waste water were 0.19, 0.29, 0.34 and 0.22 μg/L, respectively. The low detection limit, good linear range and high recoveries of C60 in environmental water indicated that the proposed method could provide an efficient approach for the analysis and tracking of C60 in the environment.
More Related Videos
10:52Radiolabeling and Quantification of Cellular Levels of Phosphoinositides by High Performance Liquid Chromatography-coupled Flow Scintillation
Published on: January 6, 2016
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Types of Detectors
Molecular Comparison of Gases, Liquids, and Solids
Rise of Liquid in a Capillary Tube