Related Experiment Video
Updated: Feb 6, 2026

Amplification of Escherichia coli in a Continuous-Flow-PCR Microfluidic Chip and Its Detection with a Capillary Electrophoresis System
Published on: November 21, 2023
Detection and Categorization of Diarrheagenic Escherichia coli with Auto-microfluidic Thin-film Chip Method
Zhenyu Yun1, Lian Zeng2, Weijian Huang3
1China National Institute of Standardization, #4 Zhichun Rd., Haidian District, Beijing, 100088, China.
Abstract:
Diarrheagenic Escherichia coli (DEC) causes human diarrhea symptom in both healthy and immunocompromised individuals. An auto-microfluidic thin-film chip (AMTC) instrument integrating one-step multiplex PCR (mPCR) with reverse dot blot hybridization (RDBH) was developed for high-throughput detection of DEC. The novel mPCR method was developed by designing 14 specific primers and corresponding probes. 14 indexes including an endogenous gene (uidA) and 13 pathogenic genes (stx1, stx2, escV, ipaH, invE, estB, lt, pic, aggR, astA, bfpB, sth and stp) of DEC were detected. This one-step mPCR + RDBH approach is useful for simultaneous detection of numerous target genes in a single sample, whose specificity and availability have been confirmed on the positive control of 11 DEC strains. In addition, with 300 diarrheal stool samples being detected by this method, 21 were found to contain five major DEC strains. Compared with monoplex PCR and previous one-step mPCR approach, this method could detect ipaH and estB, and compared with current commercial kit, the relevance ratio of DEC detected by the AMTC method was increased by 1% in stool samples. Furthermore, the novel integration AMTC device could be a valuable detection tool for categorization of E. coli.
Related Concept Videos
How Data are Classified: Categorical Data
Data are classified based on whether they are measurable or not. Categorical data cannot be measured; instead, it can be divided into categories. For example, if Y denotes a person's party affiliation, some examples of Y include...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Chemotaxis in E. coli
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Stringent Response in E. coli
Chromatin Immunoprecipitation- ChIP
Types of ChIP
ChIP can be divided into two types - X-ChIP and N-ChIP. X-ChIP involves in vivo cross-linking of histones and regulatory proteins to DNA, fragmenting the DNA by sonication, and isolating the protein-DNA...

