Related Experiment Video
Updated: Feb 6, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
Performance assessment of a software-based coincidence processor for the EXPLORER total-body PET scanner
Edwin K Leung1,2,3, Martin S Judenhofer1, Simon R Cherry1,2
1Department of Biomedical Engineering, University of California, Davis, One Shields Avenue, Davis, CA 95616, United States of America.
Post-acquisition processing of positron emission tomography (PET) singles data on the EXPLORER scanner is feasible. Faster data storage, like PCIe SSDs, significantly improves processing speed for PET imaging.
Area of Science:
- Medical Imaging
- Nuclear Medicine
- Computer Science
Background:
- Positron Emission Tomography (PET) coincidence processing is usually performed during data acquisition.
- The EXPLORER total-body PET scanner allows for storage of unpaired single events (singles) for post-acquisition processing.
Purpose of the Study:
- To develop and assess a software-based coincidence processor for the EXPLORER PET scanner.
- To evaluate the impact of data storage types on post-acquisition processing performance.
Main Methods:
- Developed a software-based coincidence processor for PET data.
- Assessed processor performance using different data storage solutions (PCIe SSD vs. RAID 6 HDD).
- Evaluated processing capabilities with varying numbers of computer nodes and parallel data file processing.
Main Results:
- Data storage type significantly impacts coincidence processing performance, especially with parallel processing.
- A single computer node with a PCIe SSD can process ~120 M singles/sec at an incoming rate of ~150 Mcps.
- Utilizing two computer nodes enables near real-time coincidence processing at this high singles rate.
Conclusions:
- Post-acquisition coincidence processing for PET is viable on the EXPLORER scanner.
- Optimized data storage and computational resources are crucial for efficient PET data processing.
- Near real-time processing is achievable with adequate hardware configurations.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Total Voids in Concrete
![Visualization and Quantification of Brown and Beige Adipose Tissues in Mice using [18F]FDG Micro-PET/MR Imaging](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F62460.jpg&w=3840&q=50)