Author Correction: Long range electronic phase separation in CaFe3O5.
Ka H Hong1, Angel M Arevalo-Lopez2, James Cumby1
1Centre for Science at Extreme Conditions and School of Chemistry, University of Edinburgh, Mayfield Road, Edinburgh, EH9 3JZ, UK.
This article corrects a factual error regarding charge ordering in Fig. 2. The corrected data now accurately reflects charge averaging (CA) instead of charge ordering (CO) in diffraction analysis.
Area of Science:
- Materials Science
- Crystallography
- Data Analysis
Background:
- Accurate representation of material phases is crucial for scientific integrity.
- Diffraction techniques like synchrotron (X) and neutron (N) are vital for phase fraction determination.
- Previous versions of the article contained a data misrepresentation.
Purpose of the Study:
- To correct a factual error in the legend of Figure 2.
- To ensure accurate reporting of phase fractions derived from diffraction data.
- To provide the correct interpretation of charge-averaged (CA) versus charge-ordered (CO) phases.
Main Methods:
- Review and correction of figure legends.
- Verification of data interpretation from synchrotron (X) and neutron (N) diffraction.
- Updating both PDF and HTML versions of the article.
Main Results:
- The term 'charge ordered (CO) phase' was identified as an error in the original Figure 2 legend.
- The correct term 'charge averaged (CA)' has been substituted.
- The correction has been implemented in all accessible versions of the article.
Conclusions:
- The correction ensures the accurate reporting of material phase information.
- This amendment upholds the scientific rigor of the published research.
- Readers are advised to refer to the corrected versions for accurate data interpretation.
More Related Videos
10:25Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope
Published on: September 14, 2018
06:34In vitro Reconstitution of Cytoskeletal Networks inside Phase Separated Giant Unilamellar Vesicles (GUVs)
Published on: June 20, 2025
Related Concept Videos
Milgram's Obedience to Authority
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Distance Corrections
Power Factor Correction
Phase Diagrams
¹H NMR: Long-Range Coupling
In alkenes, spin information is communicated via σ–π overlap, as seen in allylic (four-bond) and homoallylic (five-bond) couplings. These coupling interactions are stronger when the σ bond is parallel to the alkene...