Related Experiment Video
Updated: Feb 5, 2026

Role of Diffusion MRI Tractography in Endoscopic Endonasal Skull Base Surgery
Published on: July 5, 2021
Along-tract analysis of the arcuate fasciculus using the Laplacian operator to evaluate different tractography
Lia Talozzi1, Claudia Testa1, Stefania Evangelisti1
1Department of Biomedical and NeuroMotor Sciences, Functional MR Unit, University of Bologna, Bologna, Italia.
Purpose:
We propose a new along-tract algorithm to compare different tractography algorithms in tract curvature mapping and along-tract analysis of the arcuate fasciculus (AF). In particular, we quantified along-tract diffusion parameters and AF spatial distribution evaluating hemispheric asymmetries in a group of healthy subjects.
Methods:
The AF was bilaterally reconstructed in a group of 29 healthy subjects using the probabilistic ball-and-sticks model, and both deterministic and probabilistic constrained spherical deconvolution. We chose cortical ROIs as tractography targets and the developed along-tract algorithm used the Laplacian operator to parameterize the volume of the tract, allowing along-tract analysis and tract curvature mapping independent of the tractography algorithm used.
Results:
The Laplacian parameterization successfully described the tract geometry underlying hemispheric asymmetries in the AF curvature. Using the probabilistic tractography methods, we found more tracts branching towards cortical terminations in the left hemisphere. This influenced the left AF curvature and its diffusion parameters, which were significantly different with respect to the right. In particular, we detected projections towards the middle temporal and inferior frontal gyri bilaterally, and towards the superior temporal and precentral gyri in the left hemisphere, with a significantly increased volume and connectivity.
Conclusions:
The approach we propose is useful to evaluate brain asymmetries, assessing the volume, the diffusion properties and the quantitative spatial localization of the AF.
More Related Videos
13:26Measuring Connectivity in the Primary Visual Pathway in Human Albinism Using Diffusion Tensor Imaging and Tractography
Published on: August 11, 2016
06:22Ex Vivo Method for Assessing the Mouse Reproductive Tract Spontaneous Motility and a MATLAB-based Uterus Motion Tracking Algorithm for Data Analysis
Published on: September 1, 2019
Related Concept Videos
Operational Amplifiers
Real Number Operations
Vector Operations
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.
Operant Conditioning
Reinforcement in operant conditioning can be positive or negative, both of which serve to increase the likelihood of a behavior. Positive...
Second Derivatives and Laplace Operator
Consider a scalar function. The curl of its...
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...