Related Experiment Video
Updated: Feb 5, 2026

Animal Model of Implant-Associated Infections in Mice
Published on: June 27, 2025
Precision of digital implant models compared to conventional implant models for posterior single implant crowns: A
Sven Mühlemann1, Elena A Greter1, Ji-Man Park2
1Clinic of Fixed and Removable Prosthodontics and Dental Material Science, Center of Dental Medicine, University of Zurich, Zurich, Switzerland.
Objective:
To calculate the precision of the implant analog position in digital models generated from different computer-assisted design and computer-assisted manufacturing (CAD-CAM) systems compared to gypsum models acquired from conventional implant impressions.
Materials And Methods:
In five patients in need of a single implant crown, a within-subject comparison was performed applying four different manufacturing processes for the implant model. Each implant was scanned with three different intraoral scanners: iTero Cadent (ITE), Lava True Definition (LTD), and Trios 3Shape (TRI). All digital implant models were fabricated using the corresponding certified CAD-CAM workflow. In addition, a conventional impression was taken (CON) and a gypsum model fabricated. Three consecutive impressions were acquired with each impression system. Following fabrication, all implant models were scanned. The datasets were aligned by a repeated best-fit algorithm and the precision for the implant analog and the adjacent teeth was measured. The precision served as a measure for reproducibility.
Results:
Mean precision values of the implant analog in the digital models were 57.2 ± 32.6 µm (ITE), 88.6 ± 46.0 µm (TRI), and 176.7 ± 120.4 µm (LTD). Group CON (32.7 ± 11.6 µm) demonstrated a statistically significantly lower mean precision value for the implant position in the implant model as compared to all other groups representing a high reproducibility. The mean precision values for the reference ranged between 31.4 ± 3.5 µm (TRI) and 39.5 ± 16.5 µm (ITE). No statistical significant difference was calculated between the four treatment groups.
Conclusions:
The conventional implant model represented the greatest reproducibility of the implant position. Digital implant models demonstrated less precision compared to the conventional workflow.
Related Concept Videos
Pharmacokinetic Models: Comparison and Selection Criterion
Physiological models take a detailed approach by considering specific molecular processes. They can predict drug distribution, metabolism, and elimination changes, providing a comprehensive understanding of how drugs interact with the body.
Crown Ethers
Compartment Models: Single-Compartment Model
Molecular Models
The Sense of Self: Reflected Self-Appraisal and Social Comparison
Sign Convention
The normal force acts perpendicular to the beam's cross-section and can...

