Fine orientation control of an insertable robotic camera system for single incision laparoscopic surgery
Reza Yazdanpanah Abdolmalaki1, Xiaolong Liu1, Gregory J Mancini2
1Department of Mechanical, Aerospace, and Biomedical Engineering, University of Tennessee, Knoxville, Tennessee.
Background:
Insertable laparoscopic camera systems were developed to improve the minimally invasive surgeries. Robotic degrees of freedom for an insertable laparoscopic camera are required to adjust the camera's orientation and position inside an abdominal cavity.
Methods:
This paper demonstrates an insertable magnetic actuated robotic camera system with two-degree-of-freedom (2-DoF) orientation control for single incision laparoscopic surgery. The camera system design consists of an external magnetic control unit and a fully insertable camera capsule. This system features a unified mechanism for anchoring, navigating, and rotating the insertable camera capsule by externally generated rotational magnetic field from the control unit. The motor-free camera capsule is encapsulated in an one-piece housing with two ring-shaped tail-end magnets and one cylindrical central magnet. The control unit that positioned externally consists of both permanent magnets and electromagnetic coils to generate rotational magnetic field and control the camera capsule.
Results:
The experimental investigations indicated that the camera control system can achieve less than 1° control accuracies with average errors 0.594° and 0.524° for tilt motion and pan motion, respectively.
Conclusion:
The designed control system provides fine orientation control for the insertable camera capsule which guarantees proper vision for the surgeon during single incision laparoscopic surgery.
Related Concept Videos
Insertion of Single-pass Transmembrane Proteins in the RER
Integral transmembrane proteins possess transmembrane and extra membrane domains. The transmembrane domains are primarily made of 20-25 hydrophobic amino acids arranged in a helical secondary confirmation. These...
Fineness of Cement
Direct...
Fineness Modulus
Consider performing sieve analysis on sand through a set of ASTM sieves. The weight of aggregate retained in each sieve and pan placed at the bottom is recorded, as given in Column B of Table 1.
To determine the fineness modulus of...
Location and Orientation of the Heart
Methods of Documentation I: Source-Oriented Records
In an SOR, each discipline involved in patient care maintains a separate medical record section. This record-keeping method enables easy tracking of patient progress and ensures healthcare staff have access to up-to-date information.
Key Attributes include the following:
Porin Insertion in the Outer Mitochondrial Membrane
Three models describe the assembly of porins by the SAM complex and their insertion into the outer membrane. Model 1 suggests that porins are assembled outside the SAM channel as the...