Downregulated MALAT1 relates to recurrent pregnancy loss via sponging miRNAs

Yan Wang1, Hui-Ze Liu1, Yang Liu1

  • 1Department of Obstetrics, Affiliated Hospital of Weifang Medical University, China.

Recurrent pregnancy loss (RPL) is three or more times of consecutive spontaneous loss of pregnancy. The underlying cause is complicated and the etiology of over 50% of RPL patients is unclear. Metastasis associated lung adenocarcinoma transcript-1 (MALAT-1), a multiple lncRNA functions as key regulators of diverse cellular processes. In this study, we found a reduced MALAT1 level in the villus samples of 36 RPL patients. Predicted by bioinformatics tool and confirmed by dual luciferase assay, we identified that MALAT1 directly interacts with miRNAs. Subsequent functional study in HTR-8/SVneo and HUVEC cells indicated that MALAT1 modulates the cell proliferation, apoptosis, migration and invasion via directly interact with miR-383, miR-15, miR-205 and miR-375. By modulating the VEGFA expression, MALAT1 controls the capillary formation of HUVEC cells. In conclusion, MALAT1 as a functional lncRNA controls cell proliferation, apoptosis, migration, invasion and modulates blood vessel formation. Down regulated MALAT1 induced disordered cross-talk between embryo and mother is one of the factor contributes to the pathogenesis of RPL.

Related Concept Videos

Receptor Downregulation in MVBs01:15

Receptor Downregulation in MVBs

Multivesicular bodies (MVBs) are mature endosomes that sort ubiquitinated proteins and then fuse with lysosomes to degrade the sorted proteins. Epidermal growth factor (EGF) and its receptor (EGFR) form a complex that can be internalized through endocytosis, sorted into an MVB, and later degraded.
The EGFR can initiate signaling pathways that  lead to cell proliferation, migration, and differentiation. Overexpression of EGFR  stimulates cells to proliferate. Excessive  EGFR...
2.8K
Line Loss01:10

Line Loss

The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
545
Reducing Line Loss01:18

Reducing Line Loss

In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
390
Relative Risk01:12

Relative Risk

Relative risk (RR) is a statistical measure commonly used in epidemiology to compare the likelihood of a particular event occurring between two groups. This metric is important for evaluating the relationship between exposure to a specific risk factor and the probability of a particular outcome. It plays a crucial role in medical research, public health studies, and risk assessment. Relative risk quantifies how much more (or less) likely an event is to occur in an exposed group compared to an...
2.2K
Energy Losses in Transformers01:21

Energy Losses in Transformers

In an ideal transformer, it is assumed that there are no energy losses, and, hence, all the power at the primary winding is transferred to the secondary winding. However, in reality,  the transformers always have some energy losses, and, hence, the output power obtained at the secondary winding is less than the input power at the primary winding due to energy losses.
There are four main reasons for energy losses in transformers.
The first cause can be  the high resistance of the...
1.3K
Major Losses in Pipes01:28

Major Losses in Pipes

When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
2.0K