Related Experiment Video
Updated: Feb 5, 2026

Quantitative Fundus Autofluorescence for the Evaluation of Retinal Diseases
Published on: March 11, 2016
Evaluating a Portable, Noncontact Fundus Camera for Retinopathy of Prematurity Screening by Nonophthalmologist Health
S Grace Prakalapakorn1, Sharon F Freedman1, Amy K Hutchinson2
1Duke University, Department of Ophthalmology, Durham, NC, USA.
Purpose:
To evaluate (1) the feasibility of non-ophthalmologist healthcare workers (HCWs) to obtain images of sufficient quality for retinopathy of prematurity (ROP) screening using a FDA-approved portable, non-contact, narrow-field fundus camera (i.e., Pictor™), and (2) the accuracy of grading these images to identify infants who developed treatment-warranted (type 1) ROP.
Design:
Prospective cohort study.
Subjects:
Infants undergoing routine ROP screening examinations (i.e. birth weight ≤1500 grams and/or gestational age ≤30 weeks or selected infants with a birth weight of 1500-2000g or gestational age >30 weeks and an unstable clinical course).
Methods:
We prospectively recruited infants undergoing ROP screening examinations at a community hospital. On the same day an ophthalmologist examined them, a trained HCW imaged their retinas using the non-contact camera. Two masked ROP experts graded these images remotely. We calculated both the percentage of gradable images (i.e. having at least 3 quadrants with sufficient image quality), as well as the accuracy of identifying infants who developed type 1 ROP.
Main Outcome Measures:
Percentage of gradable images and the sensitivity and specificity of each grader for identifying infants with type 1 ROP by grading for the presence of pre-plus or plus disease.
Results:
Ninety-nine infants were included. Overall, 92.4% and 94.2% of all infant imaging sessions were considered gradable by graders 1 and 2, respectively. Amongst gradable images, the sensitivity of both graders for identifying type 1 ROP by grading for the presence of pre-plus or plus disease was 100% (95% confidence interval (CI): 95-100%) and the specificity 91% (95% CI: 83-95%) for grader 1 and 93% (95% CI: 86-96%) for grader 2.
Conclusions:
It was highly feasible for trained HCWs to obtain digital retinal images of sufficient quality for ROP screening using a non-contact fundus camera. By grading for the presence of pre-plus or plus disease, graders identified infants who developed type 1 ROP with high sensitivity and specificity. The use of portable, non-contact retinal cameras by trained HCWs could increase our workforce in ROP screening and identify infants needing an indirect ophthalmoscopy examination by an ophthalmologist.
Related Concept Videos
Interdisciplinary Care: The Health Care Team-I
Physicians
The physician's primary responsibility is to diagnose illness and direct the medical or surgical treatment of the condition. The authority to admit patients to a healthcare agency or institution and practice care within that setting is granted to physicians by the healthcare agency or institution...
Interdisciplinary Care: The Health Care Team-II
Physical Therapist
A physical therapist (PT) aims to restore function or prevent additional impairment in a patient following an injury or disease. Massage, heat, cold, water, sonar waves, exercises, and electrical stimulation are some treatments used by PTs to treat...
Introduction To Health Care Delivery System
The Institute of Medicine (IOM) advocates for a patient-centered, effective, safe, timely, equitable, and effective healthcare system. The National Priorities...
Traditional Level Of Health Care System
The preventive healthcare service includes tests for screening. Preventive health care services include identifying and reducing disease risk...
Health Literacy
Continuing Care

