Related Experiment Video
Updated: Feb 5, 2026

Ultrasonographic Assessment During Cardiopulmonary Resuscitation
Published on: October 24, 2020
Ultra-low tidal volume ventilation-A novel and effective ventilation strategy during experimental cardiopulmonary
Robert Ruemmler1, Alexander Ziebart1, Christian Moellmann1
1Department of Anesthesiology, Medical Center of the Johannes Gutenberg-University, Langebeckstrasse 1, 55116 Mainz, Germany.
Background:
The effects of different ventilation strategies during CPR on patient outcomes and lung physiology are still poorly understood. This study compares positive pressure ventilation (IPPV) to passive oxygenation (CPAP) and a novel ultra-low tidal volume ventilation (ULTVV) regimen in an experimental ventricular fibrillation animal model.
Study Design:
Prospective randomized controlled trial.
Animals:
30 male German landrace pigs (16-20 weeks).
Methods:
Ventricular fibrillation was induced in anesthetized and instrumented pigs and the animals were randomized into three groups. Mechanical CPR was initiated and ventilation was either provided by means of standard IPPV (RR: 10/min, Vt: 8-9 ml/kg, FiO2: 1,0, PEEP: 5 mbar), CPAP (O2-Flow: 10 l/min, PEEP: 5 mbar) or ULTVV (RR: 50/min, Vt: 2-3 ml/kg, FiO2: 1,0, PEEP: 5 mbar). Guideline-based advanced life support was applied for a maximum of 4 cycles and animals achieving ROSC were monitored for 6 h before terminating the experiment. Ventilation/perfusion ratios were performed via multiple inert gas elimination, blood gas analyses were taken hourly and extended cardiovascular measurements were collected constantly. Brain and lung tissue samples were taken and analysed for proinflammatory cytokine expression.
Results:
ULTVV provided sufficient oxygenation and ventilation during CPR while demanding significantly lower respiratory and intrathoracic pressures. V/Q mismatch was significantly decreased and lung injury was mitigated in surviving animals compared to IPPV and CPAP. Additionally, cerebral cytokine expression was dramatically reduced.
Conclusion:
Ultra-low-volume ventilation during CPR in a porcine model is feasible and may provide lung-protective benefits as well as neurological outcome improvement due to lower inflammation. Our results warrant further studies and might eventually lead to new therapeutic options in the resuscitation setting.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Cardiopulmonary Resuscitation I: Adult
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Pulmonary Ventilation: Inhalation
Boyle's law becomes particularly pertinent when examining respiratory...
Cardiopulmonary Resuscitation III: AED Use