Related Experiment Video
Updated: Feb 5, 2026

Assessment of Sensory Thresholds in Dogs Using Mechanical and Hot Thermal Quantitative Sensory Testing
Published on: October 26, 2021
Photography-based method for assessing fluorescein clearance test in dogs
Arianne Pontes Oriá1, Miriam Flores Rebouças2, Emanoel Martins Filho2
1School of Veterinary Medicine and Zootechny, Federal University of Bahia, UFBA, Salvador, Bahia, Brazil. arianneoria@ufba.br.
A new photography-based fluorescein clearance test (FCT) is a practical method for assessing canine tear film dynamics. Using two drops of fluorescein provides longer retention than one drop in dogs.
Area of Science:
- Veterinary Ophthalmology
- Ocular Surface Disease
- Diagnostic Imaging
Background:
- The fluorescein clearance test (FCT) is crucial for evaluating tear film dynamics.
- Assessing FCT in dogs traditionally requires specialized equipment.
- A practical, cost-effective method for canine FCT is needed.
Purpose of the Study:
- To develop an inexpensive, photography-based method for canine fluorescein clearance testing (FCT).
- To evaluate the retention time of one versus two drops of fluorescein on the canine ocular surface.
- To establish the reliability of this new FCT method in dogs.
Main Methods:
- Developed a photography and ImageJ software analysis method for FCT.
- Administered one or two drops of fluorescein to the eyes of eight German Shepherd dogs under topical anesthesia.
- Collected fluorescein-impregnated Schirmer strips at timed intervals (10 min to 72 hours) for imaging and analysis.
Main Results:
- The photography-based FCT demonstrated high repeatability and reproducibility (CV ≤ 2.75%).
- Two fluorescein drops resulted in significantly greater fluorescein uptake area and intensity at 30-40 minutes compared to one drop.
- Residual fluorescein was <5% at 60 min (1 drop) and 90 min (2 drops).
Conclusions:
- Photography-based FCT is a practical and reliable diagnostic tool for veterinary medicine.
- Two fluorescein drops enhance retention on the anesthetized canine ocular surface compared to a single drop.
- The fluorescein clearance time for a single drop in dolichocephalic dogs is approximately 60 minutes.
Related Concept Videos
Determination of Renal Drug Clearance: Graphical and Midpoint Methods
The graphical method involves plotting the rate of drug excretion in urine against the plasma drug concentration. By analyzing the graph, the clearance can be calculated and obtained. Drugs rapidly excreted by the kidneys exhibit a...
Renal Drug Clearance: Comparison Between Renal Excretion Methods
Renal clearance is often associated with the renal glomerular filtration rate (GFR), which represents the rate at which plasma is filtered through the glomeruli in the kidney. When drug reabsorption is minimal and there is no active secretion, renal clearance is closely related to the...
Hepatic Drug Clearance: Restrictive and Nonrestrictive Clearance
Most drugs undergo restrictive clearance, which is proportional to the...
Renal Clearance
Renal clearance refers to the volume of plasma cleared of a specific substance, such as creatinine, per unit of time. To measure clearance, urine samples are collected over a 24-hour period during each bladder voiding, followed by a single blood sample at the...
Drug Clearance: Overview
Drug clearance is not limited to renal excretion but encompasses all organs involved in drug elimination, including...
Clearance Models: Physiological Models
The organ's clearance rate depends on the blood flow to the organ and the extraction ratio (E). The extraction ratio describes the organ's...

