Related Experiment Video
Updated: Feb 5, 2026

X-ray Beam Induced Current Measurements for Multi-Modal X-ray Microscopy of Solar Cells
Published on: August 20, 2019
Multi-beam echo-sounder bathymetric measurements: Implications of using frequency modulated pulses
Tannaz H Mohammadloo1, Mirjam Snellen1, Dick G Simons1
1Acoustics Group, ANCE, Department of Control & Operations, Faculty of Aerospace Engineering, Delft University of Technology, 2629 HS, Delft, The Netherlands.
Abstract:
In this contribution bathymetric uncertainties induced by the use of frequency modulated (FM) signals for multi-beam-echo-sounder (MBES) measurements are quantified and their relevance for MBES bathymetric uncertainty predictions is assessed. When switching to FM, the quality of depth measurements can get deteriorated due to the Doppler effect and baseline decorrelation. The uncertainty due to the former is divided into second-order (imperfectness of the Doppler-range correction) and first-order (effect on beamsteering) effects. The latter also holds for continuous wave (CW) signals. Here, situations of relevance for measurements in the continental shelf and ship dynamics associated to rough and calm sea-states are considered, and the vertical uncertainty induced by the above sources is quantified. The influence of the Doppler effect depends on the sea state, but is found to potentially have a significant contribution to the MBES error budget for both FM and CW [nearly 82% (rough) and 68% (calm) of the total uncertainty]. The effect of baseline decorrelation depends on the actual pulse shape. For the specifications investigated, vertical uncertainties induced by this source are predicted to be larger for FM than that of CW. This is confirmed by a comparison between the modelled and measured effect on depth uncertainties when switching to FM.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Special considerations while measuring pulse
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Pulse
The pulse serves as a clinical...
Pulse
Pulse Rate and its Significance
Pulse rate, often measured in beats per minute (bpm), reflects the heart rate (HR), which is influenced by numerous factors such as stress, physical activity, and hormonal changes. A normal resting adult pulse rate falls...
Frequency-dependent Selection

