Sensitive and robust LC-MS/MS analysis of digoxin in human plasma through optimization of in-source adduct formation
Stephanie Keane1, Geoff Wallace1, Coral Munday1
1LGC Limited, Fordham, Cambridgeshire, CB7 5WW, UK.
Aim:
To develop and validate an LC-MS/MS assay for the quantification of digoxin in human plasma. An LLOQ of 10 pg/ml using a 100 μl sample was required to support drug-drug interactions studies.
Results:
Digoxin formed multiple precursor ions in positive and negative ESI and methods based on several of these have been reported previously. After screening viable precursor ions, we found the ammonium adduct gave the best combination of sensitivity and selectivity on our LC-MS/MS platform. Samples were extracted using a simple liquid-liquid procedure.
Conclusion:
The assay was successfully validation to current EMA guidelines. To the best of our knowledge the developed assay is the most sensitive published to date.
Related Concept Videos
Mesh Analysis with Current Sources
Current Source in One Mesh: The analysis process is straightforward when a current source is found in only one mesh within the circuit. Mesh currents are assigned as usual, with the mesh containing the current source excluded from the analysis. Kirchhoff's voltage law...
Nodal Analysis with Voltage Sources
Consider a circuit that contains four resistors and two voltage sources, as shown in Figure 1. One of these voltage sources is connected between a...
Optimal Foraging
Optimization Problems
Sinusoidal Sources
In homes, the power supplies use sinusoidal sources to provide electricity. These sources generate a voltage that varies sinusoidally...
AC Sources