Gradient-echo and spin-echo blood oxygenation level-dependent functional MRI at ultrahigh fields of 9.4 and 15.2
SoHyun Han1,2, Jeong Pyo Son1,3, HyungJoon Cho4
1Center for Neuroscience Imaging Research, Institute for Basic Science (IBS), Suwon, South Korea.
Purpose:
Sensitivity and specificity of blood oxygenation level-dependent (BOLD) functional MRI (fMRI) is sensitive to magnetic field strength and acquisition methods. We have investigated gradient-echo (GE)- and spin-echo (SE)-BOLD fMRI at ultrahigh fields of 9.4 and 15.2 Tesla.
Methods:
BOLD fMRI experiments responding to forepaw stimulation were performed with 3 echo times (TE) at each echo type and B0 in α-chloralose-anesthetized rats. The contralateral forelimb somatosensory region was selected for quantitative analyses.
Results:
At 9.4 T and 15.2 T, average baseline T2* (n = 9) was 26.6 and 17.1 msec, whereas baseline T2 value (n = 9) was 35.7 and 24.5 msec, respectively. Averaged stimulation-induced ΔR2* was -1.72 s-1 at 9.4 T and -3.09 s-1 at 15.2 T, whereas ΔR2 was -1.19 s-1 at 9.4 T and -1.97 s-1 at 15.2 T. At the optimal TE of tissue T2* or T2 , BOLD percent changes were slightly higher at 15.2 T than at 9.4 T (GE: 7.4% versus 6.4% and SE: 5.7% versus 5.4%). The ΔR2* and ΔR2 ratio of 15.2 T to 9.4 T was 1.8 and 1.66, respectively. The ratio of the macrovessel-containing superficial to microvessel-dominant parenchymal BOLD signal was 1.73 to 1.76 for GE-BOLD versus 1.13 to 1.19 for SE-BOLD, indicating that the SE-BOLD contrast is less sensitive to macrovessels than GE-BOLD.
Conclusion:
SE-BOLD fMRI improves spatial specificity to microvessels compared to GE-BOLD at both fields. BOLD sensitivity is similar at the both fields and can be improved at ultrahigh fields only for thermal-noise-dominant ultrahigh-resolution fMRI.
Related Concept Videos
Echo
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Oxygen Transport in the Blood
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Characteristics and Functions of Blood
The primary function of blood is to transport oxygen and carbon dioxide between tissues and the lungs. Oxygenated blood is bright red, while oxygen-depleted blood is darker. It also carries...
NMR Spectroscopy: Spin–Spin Coupling
Spin–Spin Coupling: One-Bond Coupling