Related Experiment Video
Updated: Feb 5, 2026

Four-Dimensional Computed Tomography-Guided Valve Sizing for Transcatheter Pulmonary Valve Replacement
Published on: January 20, 2022
Quadruple Valve Replacement for Carcinoid Heart Disease
Syed Saleem Mujtaba1, Stephen Clark1
1Freeman Hospital Newcastle, United Kingdom of Great Britain and Northern Ireland.
Introduction:
Carcinoid heart disease most frequently involves the tricuspid or, more rarely, the pulmonary valve and presents with right heart failure as 5-HT is metabolized by the lung. Left-sided valve involvement is quite rare. We describe our experience of 3 patients presenting with heart failure secondary to carcinoid heart disease affecting all four cardiac valves. There are only four previous isolated case reports in the literature.
Methods:
All three patients underwent quadruple valve replacement during a single operation. Right ventricular outflow tract reconstruction with a pericardial patch was performed in all patients. For 24 hours prior to surgery, all patients received intravenous octreotide, which continued in intensive care for at least 24 hours.
Results:
Mean cross-clamp and bypass times were 175 (range 164-197 minutes) and 210 (range 195-229 minutes) minutes, respectively. Mean intensive treatment unit (ITU) and inpatient stays were 2.3 (range 2-3 days) and 12 (range 9-16 days) days, respectively. One patient was reopened for bleeding 4 hours postoperatively from a ventricular pacing wire site. None required a permanent pacemaker postoperatively. There were no other complications in any patient. The quality of life was excellent at 6-16 months clinic follow-up as they were in NYHA 1. Postoperative echocardiography showed no paravalvular leaks and well-functioning prostheses in all cases.
Conclusion:
Surgery to replace all four valves is feasible with excellent medium-term survival and a very low rate of complications. Patients with carcinoid heart disease should always be considered for surgery irrespective of the extent of valvular involvement.
More Related Videos
05:31Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
14:14Standardized Technique of Aortic Valve Re-implantation for Valve-sparing Aortic Root Replacement
Published on: December 11, 2017
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Rheumatic Heart Disease I: Introduction
Ischemic Heart Disease: Overview
Atherosclerosis, the primary malefactor, orchestrates this dangerous condition. It manifests as the accumulation of fatty deposits, akin to insidious plaques, within arterial walls. As time elapses, these plaques metamorphose, hardening and...
Anatomy of the Heart
Rheumatic Heart Disease III: Medical Management
Rheumatic Heart Disease IV: Nursing Management