Related Experiment Video
Updated: Feb 5, 2026

Laboratory-determined Phosphorus Flux from Lake Sediments as a Measure of Internal Phosphorus Loading
Published on: March 6, 2014
Recent sediment flux to the Ganges-Brahmaputra-Meghna delta system
Munsur Rahman1, Maruf Dustegir1, Rezaul Karim1
1Institute of Water and flood Management (IWFM), Bangladesh University of Engineering & Technology (BUET), Dhaka, Bangladesh.
Abstract:
The physical sustainability of deltaic environments is very much dependent on the volume of water and sediment coming from upstream and the way these fluxes recirculate within the delta system. Based on several past studies, the combined mean annual sediment load of the Ganges-Brahmaputra-Meghna (GBM) systems has previously been estimated to vary from 1.0 to 2.4 BT/year which can be separated into components flowing from the Ganges (260 to 680 MT/year) and Brahmaputra (390 to 1160 MT/year). Due to very limited data and small contribution of the Meghna system (6-12 MT/year) to the total sediment flux of the GBM system, the data of the Meghna is not considered in the analysis assuming the sediment flux from GB system as the sediment flux of GBM. However, in this paper our analysis of sediment concentration data (1960-2008) collected by Bangladesh Water Development Board shows that the sediment flux is much lower: 150 to 590 MT/year for the Ganges versus 135 to 615 MT/year for the Brahmaputra, with an average total flux around 500 MT/year. Moreover, the new analysis provides a clear indication that the combined sediment flux delivered through these two major river systems is following a declining trend. In most of the planning documents in Bangladesh, the total sediment flux is assumed as a constant value of around 1 billion tons, while the present study indicates that the true value may be around 50% lower than this (with an average decreasing trend of around 10 MT/year).
Related Concept Videos
The Delta-to-Delta Circuit
The Y-to-Delta Circuit
The initial step in analyzing a wye-to-delta circuit is to assume a positive phase sequence. These phase voltages are then utilized to calculate the line voltages that occur directly across the delta-connected load impedances. Van, Vbn, and Vcn are the phase voltages in wye, and Vab, Vbc, and Vca are the line voltages for a delta circuit. The relation between...
The Delta-to-Y Circuit
Electric Flux
Magnetic Flux
Suppose a surface is divided into elements of area dA. For each element, the component of the magnetic field that is normal to the...
Calculation of Electric Flux

