Vascular conspicuity differs among injection protocols and scanner types for canine multiphasic abdominal computed tomographic angiography
Related Experiment Video
Updated: Feb 5, 2026

Two-Dimensional X-Ray Angiography to Examine Fine Vascular Structure Using a Silicone Rubber Injection Compound
Published on: January 7, 2019
Florence Thierry1, Jennifer Chau2, Mariano Makara2
1The Royal (Dick) School of Veterinary Studies and Roslin Institute, The University of Edinburgh, Roslin, EH25 9RG, UK.
Abstract:
Multiphasic multidetector computed tomographic angiography is a standard diagnostic test for canine abdominal vascular disorders. Three imaging protocols have been previously described. The test-bolus protocol allows precise timing but can be time consuming to perform. Bolus-tracking software is fast and easy to use but can be problematic for exact timing of vascular phases. A recently described fixed-injection-duration protocol is not influenced by body weight and provides a wider temporal window for arterial acquisitions. Objectives of this retrospective and prospective, multicentric, method comparison study were to determine which of the three multidetector computed tomographic angiography protocols allows best vascular conspicuity of the canine abdomen and to assess the influence of different multidetector computed tomography (CT) scanners on study quality. Triple-phase multidetector computed tomographic angiography canine abdominal studies from 30 dogs were retrospectively retrieved from three different institutions. Each institution performed one of the three computed tomographic angiography protocols (4-row and 16-row multidetector CT). Prospectively, the three protocols were also acquired with similar conditions on a 64-row MDCT in 21 dogs. Main abdominal vessels were scored by blinded readers for each phase. The fixed-injection-duration protocol had the best combined arterial and portal vascular conspicuity on scanners of limited speed, while the test-bolus protocol provided the best overall vascular conspicuity on 64-row multidetector CT scanner. The quality of arterial studies performed on 64-row MDCT scanner was improved compared to the ones performed on four- to 16-row multidetector CT scanners. Findings supported the fixed-injection-duration protocol as the best compromise between an ideal portal vascular enhancement and an easily reproducible protocol on scanners with low and high number of detector rows.
Related Concept Videos
Abdominal Aorta
The celiac trunk, a singular artery, divides into the left gastric artery, which...
Seedless Vascular Plants
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Identifying Statistically Significant Differences: The F-Test
Sum and Difference OpAmps
A summing amplifier, or an adder, utilizes an op-amp to merge multiple input signals into a single output signal. When audio signals are introduced into its input channels, the input resistors initiate currents that traverse feedback resistors, resulting in an output voltage. Applying Kirchhoff's current...