Related Experiment Video
Updated: Feb 5, 2026

The Cutting and Floating Method for Paraffin-embedded Tissue for Sectioning
Published on: September 5, 2018
Impact of storage conditions on the quality of nucleic acids in paraffin embedded tissues
Daniel Groelz1, Christian Viertler2, Daniela Pabst2
1QIAGEN GmbH, Research and Development, Hilden, Germany.
Abstract:
RNA and DNA analyses from paraffin-embedded tissues (PET) are an important diagnostic tool for characterization of a disease, exploring biomarkers and treatment options. Since nucleic acids from formalin-fixed and paraffin-embedded (FFPE) tissue are of limited use for molecular analyses due to chemical modifications of biomolecules alternate, formalin-free fixation reagents such as the PAXgene Tissue system are of evolving interest. Furthermore, biomedical research and biomarker development critically relies on using long-term stored PET from medical archives or biobanks to correlate molecular features with long-term disease outcomes. We therefore performed a comparative study to evaluate the effect of long term storage of FFPE and PAXgene Tissue-fixed and paraffin-embedded (PFPE) tissue at different temperatures on nucleic acid stability and usability in PCR. Matched FFPE and PFPE human tissues from routine clinical setting or rat tissues from a highly controlled animal model were stored at room temperature and 4°C, as well as in case of animal tissues frozen at -20°C and -80°C. RNA and DNA were extracted in intervals for up to nine years, and examined for integrity, and usability in quantitative RT-PCR (RT-qPCR) or PCR (qPCR) assays. PET storage at room temperature led to a degradation of nucleic acids which was slowed down by storage at 4°C and prevented by storage at -20°C or -80°C. Degradation was associated with an amplicon length depending decrease of RT-qPCR and qPCR efficiency. Storage at 4°C improved amplifiability in RT-qPCR and qPCR profoundly. Chemically unmodified nucleic acids from PFPE tissue performed superior compared to FFPE tissue, regardless of storage time and temperature in both human and rat tissues. In conclusion molecular analyses from PET can be greatly improved by using a non-crosslinking fixative and storage at lower temperatures such as 4°C, which should be considered in prospective clinical studies.
Related Concept Videos
Nucleic Acids
DNA and RNA
The two main types of nucleic acids are deoxyribonucleic acid (DNA) and ribonucleic acid (RNA). DNA is the genetic material in all living organisms, ranging from single-celled bacteria to multicellular mammals. It is in the nucleus of eukaryotes and in the organelles, chloroplasts, and mitochondria. In prokaryotes,...
Nucleic acids
DNA and RNA
The two main types of nucleic acids are deoxyribonucleic acid (DNA) and ribonucleic acid (RNA). DNA is the genetic material in all living organisms, ranging from single-celled bacteria to multicellular mammals. It is in the nucleus of eukaryotes and in the organelles, chloroplasts, and mitochondria. In prokaryotes,...
Nucleic Acids
Nucleic Acid Structure
DNA Structure
DNA...
Nucleic Acids and Nucleotides
Deoxyribonucleic Acid (DNA)
DNA is the genetic material in all living organisms, ranging from single-celled bacteria to multicellular mammals. It is in the nucleus of eukaryotes and the organelles such as chloroplasts and mitochondria....
Biosynthesis of Nucleic Acids

