The electrical activity map of the human skin indicates strong differences between normal and diabetic individuals: A
Constantin Ionescu-Tirgoviste1, Paul A Gagniuc2, Elvira Gagniuc3
1National Institute of Diabetes, Nutrition and Metabolic Diseases "N.C. Paulescu", Bucharest, Romania.
Abstract:
The human skin is not only the largest organ, but also the most important candidate for novel non-invasive methods of investigation. Here we describe a large-scale prototype for determining the real-time distribution of the electrical activity from the surface of the human skin. A collection of 200 sensors have been placed across the entire trunk surface. The output of each sensor was remotely inserted into a 20 × 10 LED matrix for a parallel capture of the signals. Continuous observations of the electrical activity pattern were made above the LED matrix by a digital camera in an obscure environment. A total of 5.2 million measurements (25,920 maps) have been recorded as light intensities from the LED matrix and converted into percentages for evaluation. A total of 36 individuals were divided equally into two groups and subjected to a short glucose tolerance test for 1 h; one group with established Type 2 Diabetes (T2D) and the other group without diabetes. The electrical activity pattern and the average signal intensity of normal individuals (37% ± 8.1) and diabetic individuals (58% ± 7.8), showed a significant difference of 21%. The average signal intensity on the ventral side (VS) and dorsal side (DS) of the torso exhibited different behaviors in diabetics and non-diabetics. On average, diabetic individuals have shown an electrical activity of higher intensity on DS (DS = 60%, VS = 55%), while the normal group has shown a higher intensity on VS (DS = 36%, VS = 39%).
More Related Videos
Related Concept Videos
Electric Potential and Potential Difference
When a test charge moves from the initial to the final position, the electric potential difference between those positions is defined as the ratio of the change in the potential energy to the charge on the...
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Strong Acid and Base Solutions
Titration of a Strong Acid with a Strong Base
Variation: Normal Distribution, Range, and Standard Deviation
Impact of Individuals on Individuals